Steam Requirements

1

SUPPLY

2

8

7

6

5

4

3

3

9

10

RETURN

2

TMB2024N

NOTE: Refer to Table 6 for sizing of steam lines. Piping must also be sized accordingly for length of runs and number

of elbows.

 

 

 

1

Risers 12 in. (305 mm)

6

18 in. Drop (457 mm)

2

Shut-Off Valve

7

Steam Bonnet

3

Check Valve

8

Solenoid Valve (Supplied with machine)

4

Vacuum Breaker (optional)

9

Union

5

Condensate Return Line from Supply Line

10

Trap with Built-In Strainer

Figure 3

Model

Steam Pressure

Minimum

Steam Trap Size *

PSI (bar)

Supply Pipe Diameter

(Pounds Condensate/Hour)

 

200S

80-100 (5.3-6.9)

1-1/4 in. NPT

517

* Based on maximum psi.

Table 6

Page 11 of 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Page 11
Image 11
Alliance Laundry Systems 70420801 Steam Requirements, Steam Pressure, Pounds Condensate/Hour, Supply Return