Page 11 of 12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Steam Requirements
Figure 3
TMB2024N
NOTE: Refer to Table 6 for sizing of steam lines. Piping must also be sized accordingly for length of runs and number
of elbows.
1Risers 12 in.
(305 mm) 618 in. Drop (457 mm)
2Shut-Off Valve 7Steam Bonnet
3Check Valve 8Solenoid Valve (Supplied with machine)
4Vacuum Breaker (optional) 9Union
5Condensate Return Line from Supply Line 10 Trap with Built-In Strainer
TMB2024N
SUPPLY
2
1
9
3
RETURN
2
3
710
4
5
8
6
Model Steam Pressure
PSI (bar)
Minimum
Supply Pipe Diameter
Steam Trap Size *
(Pounds Condensate/Hour)
200S 80-100 (5.3-6.9) 1-1/4 in. NPT 517
* Based on maximum psi.
Table 6