3.Remove back panel and check overflow hose and drain hose for leaks.

4.Unlock the hinged lid and check the supply dispenser hoses and hose connections.

5.Clean inlet hose filter screens:

a.Turn water off and allow valve to cool, if necessary.

b.Unscrew inlet hose and remove filter screen.

c.Clean with soapy water and reinstall. Replace if worn or damaged.

6.Tighten motor mounting bolt locknuts and bearing bolt locknuts, if necessary.

7.Use compressed air to clean lint from motor.

8.Clean interior of machine, both basket and shell, by wiping with a water-soaked sponge or cloth.

9.Use compressed air to ensure that all electrical components are free of moisture and dust.

10.For variable-speed models only, clean AC drive cooling fan blades monthly (more often if required by the condition of the air).

a.Open the top cover and remove the control module cover.

b.Gently wipe the fan blades clean with a dry cloth.

Quarterly

NOTE: Disconnect power to the machine before performing the quarterly maintenance procedures.

1.Tighten door hinges and fasteners, if necessary.

2.Tighten anchor bolts, if necessary.

3.Verify that the drain motor shield is in place and secure, if so equipped.

Maintenance

4.Check all painted surfaces for exposed metal. (Matching paint is available from the manufacturer.)

If bare metal is showing, paint with primer or solvent-based paint.

If rust appears, remove it with sandpaper or by chemical means.

Then paint with primer or solvent-based paint.

5.Clean customer-supplied steam filter, where applicable. Refer to Figure 12.

a.Turn off steam supply and allow time for the valve to cool.

b.Unscrew cap.

c.Remove element and clean.

d.Replace element and cap.

1

2

H042I

H042I

1Cap

2Filter Element

Figure 12

F232219

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

19