Nameplate Location

The nameplate is located at the rear of the machine and inside door. Always provide the machine’s serial number and model number when ordering parts or when seeking technical assistance.

1

CHM2060N

1Nameplate

Figure 1

Replacement Parts

If literature or replacement parts are required, contact the source from whom the machine was purchased or contact Alliance Laundry Systems at (920) 748-3950 for the name and address of the nearest authorized parts distributor.

Customer Service

For technical assistance, call: (920) 748-3121 Ripon, Wisconsin.

Introduction

Summary of Control Outputs and Inputs

Outputs

General outputs provide signals to operate the following components.

1.Hot Fill Valve

2.Cold Fill Valve

3.Drain Valve (normally open)

4.Door Lock Solenoid Coil

5.Door Unlock Solenoid Coil

6.Supply 1 (detergent)

7.Supply 2 (bleach)

8.Supply 3 (sour/softener)

9.Supply 4

10.Supply 5 or Optional 3rd (auxiliary) Fill Inlet (governed by the configuration settings)

11.Optional Heat

For standard models, the components for outputs shown as “optional” will not be populated on the output printed circuit board.

AC outputs are solid state outputs that operate either 120 Volt AC or 220 Volt AC (nominal voltage) components, depending on the control voltage configuration. Outputs are fused appropriately.

Inputs

1.Low Water Level

2.Medium Water Level

3.High Water Level

4.Door

5.Temperature Signal (only for machines with heat option)

Control Voltage

The control power supply can be configured to operate on 110 Volt AC nominal RMS input voltage

50/60 Hertz, OR 220 Volt AC nominal RMS input voltage 50/60 Hertz.