Nameplate Location
The nameplate is located at the rear of the machine and inside door. Always provide the machine’s serial number and model number when ordering parts or when seeking technical assistance.
1
CHM2060N
1Nameplate
Figure 1
Replacement Parts
If literature or replacement parts are required, contact the source from whom the machine was purchased or contact Alliance Laundry Systems at (920)
Customer Service
For technical assistance, call: (920)
Introduction
Summary of Control Outputs and Inputs
Outputs
General outputs provide signals to operate the following components.
1.Hot Fill Valve
2.Cold Fill Valve
3.Drain Valve (normally open)
4.Door Lock Solenoid Coil
5.Door Unlock Solenoid Coil
6.Supply 1 (detergent)
7.Supply 2 (bleach)
8.Supply 3 (sour/softener)
9.Supply 4
10.Supply 5 or Optional 3rd (auxiliary) Fill Inlet (governed by the configuration settings)
11.Optional Heat
For standard models, the components for outputs shown as “optional” will not be populated on the output printed circuit board.
AC outputs are solid state outputs that operate either 120 Volt AC or 220 Volt AC (nominal voltage) components, depending on the control voltage configuration. Outputs are fused appropriately.
Inputs
1.Low Water Level
2.Medium Water Level
3.High Water Level
4.Door
5.Temperature Signal (only for machines with heat option)
Control Voltage
The control power supply can be configured to operate on 110 Volt AC nominal RMS input voltage
50/60 Hertz, OR 220 Volt AC nominal RMS input voltage 50/60 Hertz.
F232219 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 7 |