Programming

NOTE: If the wash load becomes out of balance, the machine will attempt to balance the load. After three failed attempts the display will light the leftmost digit and a lower spin will be used to complete the cycle. Refer to Figure 2.

1

1 2

3 4

5 6

<

<

CHM512R

1Out-of-Balance LED

 

 

Figure 2

 

 

 

Supply Programmed

External Chemical Supply Signal

Compartment Flushed

 

 

 

SUP0

None

None

 

 

 

SUP1

Supply 1

Compartment 1*

 

 

 

SUP2

Supply 2**

Compartment 2

 

 

 

SUP3

Supply 3

Compartment 3

 

 

 

SUP4

Supply 4

No compartment Flush*

 

 

 

SUP5

Supply 5***

No compartment Flush*

 

 

 

SUP6

Supply 6***

No compartment Flush*

 

 

 

SUP7

Supply 7

Compartment 3

 

 

 

 

Table 3

 

*NOTE: Only supply 2 (SUP2) and supply 3 (SUP3) have independent water valves to flush their respective compartment. Compartment 1 will flush whenever machine is filling with water.

External chemical supply signals and any related flush valves will activate approximately 15 seconds after machine begins to fill with water. If programmed water level is reached prior to 15 seconds, no chemical supply signal will be activated.

**NOTE: ADD BLEACH LED lights if Supply 2 is the only supply programmed. If set up for "bEEP"(refer to SETUP Mode section), buzzer will sound on and off for the first eight seconds. The Supply 2 and ADD BLEACH LED remain on for 45 seconds or until the fill is complete, whichever comes first.

***NOTE: Selecting "AFIL" (auxiliary fill) in SETUP Mode will remove supply 5 and supply 6 as optional supply signals.

12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232224