Programming
NOTE: The machines are
Entering Program Mode
1.Open machine lid.
2.Locate Program/Run switch on the computer board. This is accessed through a cutout in the metal control unit cover. This switch protrudes from the rear of the electronic control unit cover.
3.Flip switch to the left (as seen from the front of machine) to enter PROGRAM Mode.
4.Display will show temperature.
Cycle and Error Count
The control logs cycle count (total of all cycles completed).
1.To read, enter PROGRAM Mode.
2.Press START (Enter) keypad. Display will show the cycle count.
3.Press START (Enter) keypad. Display will show certain error conditions that may have been recorded by the control.
4.Read the information when consulting technical assistance as needed.
5.Step through the error log by pressing START keypad repeatedly until display reverts to normal PROGRAM Mode (“0000” or a temperature).
Setup Mode
NOTE: In SETUP Mode, certain machine functions can be configured. The settings in this mode are related to how the machine is equipped from the factory. Usually, these settings would not be changed.
NOTE: Enter SETUP Mode through the Program Mode.
1.Press (6) keypad. Display will show “FAr” or “CEL”.
NOTE: This selects whether temperatures display in degrees Fahrenheit (F) or Celsius (C), if control is equipped with a temperature sensor. Change selection by pressing ∧ or ∨ keypad.
NOTE: Changing degrees “FAr” or “CEL” only has an effect if the control has a temperature probe connected and/or heat capability.
2.Press START keypad.
3.Select “HEAt” or “noHt”. Change the selection by pressing the ∧ or ∨ keypad.
NOTE: If set for “HEAt”, the control has heat capability enabled. The
4.Press START keypad to continue to the next step.
5.Select “AFIL” or “SUP5”. For “SUP5”, a fifth or sixth supply can be programmed in a cycle step. “AFIL” allows auxiliary fills to be programmed to low, medium or high water level in a cycle step.
6.Press START keypad.
7.Select “tFIL” or “ntFL.” “tFIL” allows a temperature controlled fill to be programmed for any segment. Select “ntFL” to disable the feature.
WARNING
To avoid personal injury, recommended inlet water temperature should be no higher than 125° Fahrenheit (51° Celsius).
W709
8.Press START keypad.
9.Select “COOL” or “noCL.” “COOL” enables an automatic cooldown feature allowing cold water to flush into wash before a drain if temperature is 140°F (60°C) or above. Select “noCL” to disable feature.
10.Press START keypad.
11.Select “bEEP” (control sounds beeper during Add Bleach [Supply 2]) or “nobP” (control does NOT sound beeper during Add Bleach [Supply 2]). Change selection by pressing ∧ or ∨ keypad.
12.Press START keypad.
13.Select “Adv” or “noAd”. “Adv” enables the Rapid Advance feature. Select “noAd” to disable the feature.
14.Press START keypad.
F232224 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 7 |