3.Use the three screws from the envelope located in the cylinder to attach the power cord wires to the terminal block.
12
3
D286I
1“L1” Terminal
2Neutral Terminal
3“L2” Terminal
Figure 17
4. Tighten all screws firmly.
IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block.
5.Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet.
6.Check the continuity of the ground connection before plugging the cord into an outlet. Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet.
7.Reinstall access cover and screw.
Installation
1 | 2 |
|
3
4
D815I
1Typical
2Power Cord – Not Supplied with Dryer
3Strain Relief Nut
4Strain Relief
Figure 18
1. Remove access cover from rear of dryer.
D695I
Figure 19
510963 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 19 |