Gas Requirements

NOTE: The gas service to a gas dryer must conform with the local codes and ordinances, or in the absence of local codes and ordinances, with the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54 or the CAN/CGA-B149, National Gas Installation Code.

Natural Gas, 1000 Btu/ft3 (37.3 MJ/m3) service must be supplied at 6.5 ± 1.5 inch water column pressure.

For proper operation at altitudes above 2500 feet

(760 m) the natural gas valve spud orifice size must be reduced to ensure complete combustion. Refer to Table 1.

L.P. (Liquefied Petroleum) Gas, 2500 Btu/ft3

(93.1 MJ/m3) service must be supplied at 10 ± 1.5 inch water column pressure.

NOTE: DO NOT connect the dryer to L.P. Gas Service without converting the gas valve. An LPK1 Sales Accessory (L.P. Gas Conversion Kit 649P3) must be installed.

NOTE: The dryer and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa). Refer to Figure 13.

NOTE: When connecting to a gas line, an equipment shut-off valve must be installed within

6 feet (1.8 m) of the dryer. An 1/8 in. NPT pipe plug must be installed as shown. Refer to Figure 26.

Installation

WARNING

To reduce the risk of gas leaks, fire or explosion:

The dryer must be connected to the type of gas as shown on nameplate located in the door recess.

Use a new flexible stainless steel connector.

Use pipe joint compound insoluble in L.P. (Liquefied Petroleum) Gas, or Teflon tape, on all pipe threads.

Purge air and sediment from gas supply line before connecting it to the dryer. Before tightening the connection, purge remaining air from gas line to dryer until odor of gas is detected. This step is required to prevent gas valve contamination.

Do not use an open flame to check for gas leaks. Use a non-corrosive leak detection fluid.

Any disassembly requiring the use of tools must be performed by a suitably qualified service person.

 

 

 

 

 

 

 

W316

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas Altitude Adjustments

 

 

 

 

 

 

 

 

Altitude

 

Orifice Size

 

Part No.

 

 

 

 

 

 

 

feet

m

#

 

inches

 

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

3000

915

43

 

0.0890

 

2.26

503778

 

 

 

 

 

 

 

 

 

 

6000

1830

44

 

0.0860

 

2.18

58719

 

 

 

 

 

 

 

 

 

 

8000

2440

45

 

0.0820

 

2.08

503779

 

 

 

 

 

 

 

 

 

 

9000

2740

46

 

0.0810

 

2.06

503780

 

 

 

 

 

 

 

 

 

 

10,000

3050

47

 

0.0785

 

1.99

503781

 

 

 

 

 

 

 

 

 

 

Table 1

510963