Location Requirements

Select a location with a solid floor. Dryers installed in residential garages must be elevated 18 inches (46 cm) above the floor.

No other fuel burning appliance should be installed in the same closet with the dryer.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Installation

Leveling legs can be adjusted from inside the dryer with a 1/4 inch driver. All four legs must rest firmly on the floor so the weight of the dryer is evenly distributed. The dryer must not rock.

The dryer needs sufficient clearance and an adequate air supply for proper operation and ventilation, and for easier installation and servicing. (Minimum clearances are shown below.)

F

1

B

E

2 (G)

 

D

A

**42 in.

 

(106.7 cm)

F

A

A

C

 

FRONT VIEW

FRONT VIEW

SIDE VIEW

3

(w/o Closet Door)

(Closet Door)

 

(Closet Door)

D823I

Area

Description

Free Standing/Alcove

Closet Installation

Installation

 

 

 

 

 

 

 

A

Dryer sides and rear clearance

0 in. (0 cm)

0 in. (0 cm)

 

 

 

 

B

Dryer top clearance

12 in. (30.5 cm)

12 in. (30.5 cm)

 

 

 

 

C

Dryer front clearance

Not Applicable

2 in. (5.1 cm)

 

 

 

 

D

Exhaust duct clearance to

2 in. (5.1 cm)

2 in. (5.1 cm)

 

combustible material

 

 

 

 

 

 

E

Weather hood to ground

12 in. (30.5 cm)

12 in. (30.5 cm)

 

clearance

 

 

 

 

 

 

F

Distance from floor or ceiling to

Not Applicable

3 in. (7.6 cm)

 

hole edge

 

 

 

 

 

 

G*

Area of centered air openings in

Not Applicable

40 sq. in./open (260 sq. cm)

 

closet door

 

 

 

 

 

 

*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)