Installation

5

30°

1

A B C D E F G H I J K

AIR

FLOW

EXHAUST AIR FLOW

MAXIMUM LENGTH OF DUCT

30 feet (9.1 m)

HORIZONTAL EXHAUST INSTALLATION

2

3

4

24 in. (61 cm)

MINIMUM

EXHAUST CLEARANCE TO

OUTLET ROOF/GROUND

D686I

D686I

1

2

NOTE: Where the exhaust duct pierces a

3

2 in. (5 cm) Minimum or Clearance per Local

combustible wall or ceiling, the opening must be

 

Codes

sized per local codes.

4

No Screen or Cap

Wall

5

Clean Out Cover Inspect Monthly

Figure 7

2

3

24 in. (61 cm)

MINIMUM

CLEARANCE TO ROOF/GROUND

1

CONNECT TO DRYER

5

 

4

 

 

 

 

 

VERTICAL EXHAUST INSTALLATION

D753I

1Roof

2No Screen or Cap

3Wall

42 in. (5 cm) Minimum

5NOTE: Where the exhaust duct pierces a combustible wall or ceiling, an opening must be sized as shown or per local codes.

WARNING

To reduce the risk of fire and the accumulation of combustion gases, DO NOT exhaust dryer air into a window well, gas vent, chimney or enclosed, unventilated area, such as an attic, wall, ceiling, crawl space under a building or concealed space of a building.

W045

Figure 8