Installation

1.Disconnect power to dryer.

2.Remove access cover from rear of dryer.

5.Attach power cord ground (green) wire to rear bulkhead using ground screw removed in Step 3.

7

1

D695I

Figure 17

3.Remove ground screw and save for use in Step 5. Remove wire and use in Step 6.

1

D697I

D697I

1Ground Screw

Figure 18

4.Use a strain relief and insert end of power cord through power supply hole.

D696I

Figure 19

6

5

 

4

2

 

3 DRY1920N

DRY1920N

1White

2“L2” Terminal

3Black

4Green

5Red

6Neutral Terminal

7“L1” Terminal

Figure 20

6.Use the three screws from the accessories bag to attach the remaining power cord wires to the terminal block as follows:

a.Red wire to “L1” terminal.

b.Black wire to “L2” terminal.

c.White wire to Neutral terminal.

NOTE: When installing the white wire, loop the free eyelet end of the ground wire (removed in Step 3) and attach along with the white wire to the neutral (center) terminal on the terminal block.

7. Tighten all screws firmly.

IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block.

8.Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet.

9.Check the continuity of the ground connection before plugging the cord into an outlet. Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet.

10.Reinstall access cover and screw.

20

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

513005

Page 22
Image 22