Installation
Step 8: Recheck Steps 1-7
Refer to Installer Checklist on the back cover of this manual and make sure that dryer is installed correctly.
Step 9: Check Heat Source
Electric Dryers
Close the loading door and start the dryer in a heat setting (refer to the Operation section). After the dryer has operated for three minutes, the exhaust air or exhaust pipe should be warm.
Gas Dryers
IMPORTANT: This operation is to be conducted by qualified personnel only.
To view the burner flame, remove the lower front panel of the dryer.
Close the loading door, start the dryer in a heat setting (refer to the Operation section). The dryer will start, the igniter will glow red and the main burner will ignite.
IMPORTANT: If all air is not purged out of gas line, gas igniter may go off before gas is ignited. If this happens, after approximately two minutes igniter will again attempt gas ignition.
IMPORTANT: If igniter does not light, make sure gas is turned on.
After the dryer has operated for approximately five minutes, observe burner flame through lower front panel. Adjust the air shutter to obtain a soft, uniform blue flame. (A lazy,
1.Loosen the air shutter lockscrew.
2.Turn the air shutter to the left to get a luminous
3.After the air shutter is adjusted for proper flame, tighten the air shutter lockscrew securely.
4.Reinstall the lower front panel.
WARNING
For personal safety, lower front panel must be in place during normal operation.
W046
After the dryer has operated for approximately three minutes, exhaust air or exhaust pipe should be warm.
1
6
5
1Closed Position
2
3Air Shutter Lockscrew
4Air Shutter
2
3 |
4 |
DRY2235N
51/8 in. (3.1 mm) Pipe Plug
(For checking manifold pressure)
6Open Position
Figure 33
24 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 513005 |