Troubleshooting Chart
TROUBLE | CAUSE | REMEDY |
|
|
|
Dryer runs, but no heat | Defective thermostat | Check continuity across thermostat. Limiting or |
(continued). |
| safety thermostats are normally closed. If open, |
|
| replace thermostat. |
|
|
|
| Defective safety overload thermo- | See above. |
| stat |
|
| Lint compartment drawer open | Close drawer. |
|
|
|
Main burners | Dirt in burner | Blow out. |
burning improperly. | Gas pressure too high | Check rating plate for correct gas pressure. |
|
|
|
| Orifice too large | Send to factory for correct orifices. |
| Restricted or blocked exhaust | Clean exhaust. |
| Incorrect or poor gas mixture | Check with gas supplier for correct specifications of |
|
| gas used; must match rating plate. |
|
|
|
Low gas flame or high | Incorrect main burner orifices | Replace orifices |
gas flame. |
|
|
|
|
|
Dryer too hot. | Incorrect main burner orifices | Replace orifices |
|
|
|
| Inadequate | |
|
| of the dryer. |
|
|
|
| Lint accumulated | Remove lint. |
| Exhaust duct dampers | Must be full open when dryer is in operation or |
|
| replace. |
| Gas pressure too high | Adjust gas pressure as specified on rating plate. |
|
|
|
| Partially restricted or | Refer to Installation Manual for exhaust system |
| inadequately sized exhaust system | requirements. Check for and remove obstructions or |
|
| lint |
|
| exhaust duct. Always use larger size |
|
| exhaust duct. |
|
|
|
| Defective thermostat | When flame or heat is passed over, thermostat circuit |
|
| should open. Audible click will usually be heard. If |
|
| continuity remains, thermostat is defective. Replace |
|
| thermostat. |
Page 16