Troubleshooting Chart
TROUBLE | CAUSE | REMEDY |
|
|
|
Motor will not start. | No power | Check fuses on circuit breakers. Make sure main |
|
| control switch is ON. |
| Incorrect power | Check power source: voltage, phase, and frequency |
|
| must be the same as specified on electrical rating |
|
| plate. |
| Timeoff | Turn timer clockwise to desired time setting. |
| Loose wiring connections | Check wire connections in electrical box on rear of |
|
| dryer. |
| Defective starting relay | Check coils and contacts. |
Motor tripping on | Low voltage | Check voltage at motor teminals. Voltage must be |
thermal overload. |
| within (plus or minus) 10% of voltage shown on |
|
| motor rating plate |
|
| company for recommended corrective measures. |
| Inadequate wiring | Check with local power company to insure that |
|
| wiring is adequately sized for load. |
| Loose connections | Check all electrical connections and tighten any |
|
| loose connections. |
| Inadequate air | Refer to Installation Manual for recommended make- |
|
| up air openings. |
| Poor housekeeping | Clean lint accumulation on and around motors. |
|
| Motors should not be covered with or filled with |
|
| lint. |
Basket motor will not | Loading door open | Close door. |
run. | Door switch out of adjustment | Adjust switch by removing cover and bend actuator |
|
| lever to clear switch button 3/8” with cover in |
|
| place. |
|
|
|
| Defective door switch | Check continuity across switch with power off, in |
|
| closed and open switch. If no continuity, replace |
|
| switch. |
| Defective basket motor contactor | Push in contactor trip button. If motor starts, check |
|
| voltage going to |
|
| replace contactor. If not, problem is before motor |
|
| contactor. |
|
|
|
Basket will not reverse. | Reversing timer | Confirm timer is working. |
|
|
|
Page 17