Programming

Entering Program Mode

1.Unlock and raise top cover.

2.Remove control module cover.

3.Locate the Run/Program Mode switch near center of computer board inside control module. Refer to Figure 1.

1

2

CHM282R

1Run/Program Mode Switch

2Computer Board

Figure 1

4.Flip switch to down position to enter PROGRAM Mode. Display will show temperature of sump.

Procedures for Calibration of Temperature Probe for V-Computer Controlled Machines

1.Disconnect power to the machine. Ensure that the V-Computer has no input power applied.

2.Mount an accurate temperature sensor probe (part of temperature calibration equipment) in the bottom of the machine basket. Make sure the wires for the probe exit the top of the door to ensure that the door gasket does not leak.

3.Close door and ensure that the door is locked.

4.Open machine top cover and remove control component cover(s), if necessary, to gain access to the V-Computer and output control board.

WARNING

Dangerous voltages are present in the electrical control box(es) and at the motor terminals. Only qualified personnel familiar with electrical test procedures, test equipment, and safety precautions should attempt adjustments and troubleshooting. Disconnect power from the machine before removing the control box cover, and before attempting any service procedures.

SW005

8

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232141