Programming

Programming Setup Options

1.With display showing sump temperature, press Stop (*) key to enter SETUP Mode.

2.Use Up or Down (arrow) key to scroll through setup options. Refer to Table 1 for possible setup options and description.

Setup Options

Description

 

 

 

FAr”/“CEL

Select FAr”: degrees are displayed

 

 

in Fahrenheit.

 

 

Select CEL”: degrees are

 

 

displayed in Celsius.

 

 

 

noHt”/“HEAT

Select “noHt”: no heat is available

 

 

during a cycle regardless of

 

 

programmed temperature setting.

 

 

Select “HEAT”: heat is available as

 

 

long as a temperature is

 

 

programmed.

 

 

 

SUP5”/“AFIL

Select SUP5”: a fifth or sixth

 

 

supply can be programmed in a

 

 

cycle step.

 

 

Select AFIL”: auxiliary fills can

 

 

be programmed to low, medium or

 

 

high water level in a cycle step.

 

 

 

tFIL”/“ntFL

Select tFIL”: a temperature-

 

 

controlled fill can be programmed

 

 

for any segment. Select “ntFL”:

 

 

feature is disabled.

 

 

 

COOL”/“noCL

Select COOL”: automatic cool-

 

 

down feature is enabled allowing

 

 

cold water to flush into wash before

 

 

a drain if temperature is 140ºF or

 

 

above.

 

 

Select noCL”: feature is disabled.

 

 

 

 

 

Table 1

 

 

 

 

 

WARNING

 

 

 

To prevent personal injury, avoid contact with inlet water temperatures higher than 125° Fahrenheit (51° Celsius) and hot surfaces.

W748

3.Press the Start (#) key to accept the option and to then scroll forward to the next setup option.

4.Press the Stop (*) key anytime to exit SETUP Mode. The display will show sump temperature.

Programming a Cycle

1.With the display showing sump temperature, press the Up (arrow) key to edit a cycle. The display will show “CY01”.

NOTE: On VNV and VN2 models, 26 of the 30 cycles available are pre-programmed.

2.Press Up or Down (arrow) key until cycle to be edited is displayed. The display will show “CY01”. Press Start (#) key to begin editing selected cycle.

3.Use Up or Down (arrow) key to select agitation action. Refer to Table 2 for agitation action options. Press Start (#) key.

NOTE: This action applies to entire cycle.

Agitation Action Options

Display

Description

Percentage

 

 

 

AG 1

27 seconds forward,

90%

 

3 seconds pause,

 

 

27 seconds reverse,

 

 

3 seconds pause

 

 

 

 

AG 2

10 seconds forward,

33%

 

20 seconds pause,

 

 

10 seconds reverse,

 

 

20 seconds pause

 

 

 

 

AG 3

3 seconds forward,

10%

 

27 seconds pause,

 

 

3 seconds reverse,

 

 

27 seconds pause

 

 

 

 

AG 4

4 seconds forward,

6.7%

 

56 seconds pause,

 

 

4 seconds reverse,

 

 

56 seconds pause

 

 

 

 

 

Table 2

 

4.On VNV models only, use Up or Down (arrow) key to select agitation speed: normal (“AGSn”) or gentle (“AGSL”). Press Start (#) key.

5.Use Up or Down (arrow) key to select next option: “PUnP” or “nPnP”. This is for a future recirculation feature. It has no effect on wash cycle. Select “nPnP” and press Start (#) key.

10

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232141