Programming
Programming Setup Options1.With display showing sump temperature, press Stop (*) key to enter SETUP Mode.
2.Use Up or Down (arrow) key to scroll through setup options. Refer to Table 1 for possible setup options and description.
Setup Options | Description | |
|
|
|
“FAr”/“CEL” | Select “FAr”: degrees are displayed | |
|
| in Fahrenheit. |
|
| Select “CEL”: degrees are |
|
| displayed in Celsius. |
|
|
|
“noHt”/“HEAT” | Select “noHt”: no heat is available | |
|
| during a cycle regardless of |
|
| programmed temperature setting. |
|
| Select “HEAT”: heat is available as |
|
| long as a temperature is |
|
| programmed. |
|
|
|
“SUP5”/“AFIL” | Select “SUP5”: a fifth or sixth | |
|
| supply can be programmed in a |
|
| cycle step. |
|
| Select “AFIL”: auxiliary fills can |
|
| be programmed to low, medium or |
|
| high water level in a cycle step. |
|
|
|
“tFIL”/“ntFL” | Select “tFIL”: a temperature- | |
|
| controlled fill can be programmed |
|
| for any segment. Select “ntFL”: |
|
| feature is disabled. |
|
|
|
“COOL”/“noCL” | Select “COOL”: automatic cool- | |
|
| down feature is enabled allowing |
|
| cold water to flush into wash before |
|
| a drain if temperature is 140ºF or |
|
| above. |
|
| Select “noCL”: feature is disabled. |
|
|
|
|
| Table 1 |
|
|
|
|
| WARNING |
|
|
|
To prevent personal injury, avoid contact with inlet water temperatures higher than 125° Fahrenheit (51° Celsius) and hot surfaces.
W748
3.Press the Start (#) key to accept the option and to then scroll forward to the next setup option.
4.Press the Stop (*) key anytime to exit SETUP Mode. The display will show sump temperature.
1.With the display showing sump temperature, press the Up (arrow) key to edit a cycle. The display will show “CY01”.
NOTE: On VNV and VN2 models, 26 of the 30 cycles available are
2.Press Up or Down (arrow) key until cycle to be edited is displayed. The display will show “CY01”. Press Start (#) key to begin editing selected cycle.
3.Use Up or Down (arrow) key to select agitation action. Refer to Table 2 for agitation action options. Press Start (#) key.
NOTE: This action applies to entire cycle.
Agitation Action Options
Display | Description | Percentage |
|
|
|
AG 1 | 27 seconds forward, | 90% |
| 3 seconds pause, |
|
| 27 seconds reverse, |
|
| 3 seconds pause |
|
|
|
|
AG 2 | 10 seconds forward, | 33% |
| 20 seconds pause, |
|
| 10 seconds reverse, |
|
| 20 seconds pause |
|
|
|
|
AG 3 | 3 seconds forward, | 10% |
| 27 seconds pause, |
|
| 3 seconds reverse, |
|
| 27 seconds pause |
|
|
|
|
AG 4 | 4 seconds forward, | 6.7% |
| 56 seconds pause, |
|
| 4 seconds reverse, |
|
| 56 seconds pause |
|
|
|
|
| Table 2 |
|
4.On VNV models only, use Up or Down (arrow) key to select agitation speed: normal (“AGSn”) or gentle (“AGSL”). Press Start (#) key.
5.Use Up or Down (arrow) key to select next option: “PUnP” or “nPnP”. This is for a future recirculation feature. It has no effect on wash cycle. Select “nPnP” and press Start (#) key.