Troubleshooting

Error Codes (continued)

Display

Machine

Error Description

Error Cause

Error Condition Exit

:30

 

- Timeout waiting for Biberon

- Bad firmware in reader

 

 

 

insertion

 

 

:31

 

- Hotlisted card inserted into the

- Card hotlisted

After control destroys card, the

 

 

reader

 

error is cleared

:50

 

- Loyalty purse read error

- Bad card

 

:56

 

- Loyalty purse write error

- Bad card

 

 

 

 

 

 

Right-

All

- Network communication error

- Communication problem

Error ends at good

most

 

 

 

communication

dp lit

 

 

 

 

 

 

 

 

 

“Err”

All

- Coin error

- Invalid coin pulse(s)

Error ends after several

 

 

 

 

seconds

“Alrm”

All

- Breakin alarm error

- Service door or coin vault

Error ends after several

 

 

 

switches

seconds

“OFF”

All

- Breakin alarm shutdown error

- Service door or coin vault

Cycle power to clear error

 

 

 

switches

 

“E:FL”

Topload

- Fill error

- Maximum fill time exceeded

Cycle power to clear error

 

Frontload

 

 

 

 

WX

 

 

 

 

 

 

 

 

“E:dr”

Topload

- Drain error

- Maximum drain time

Cycle power to clear error

 

WX

 

exceeded or water sensed at

 

 

 

 

end of a spin step

 

“E:SP”

Frontload

- SPI communications error

- Internal communication

Cycle power to clear error

 

WX

 

problem

 

 

 

 

 

 

“E:OP”

Dryer

- Open temperature sensor error

- Bad sensor or wiring

Cycle power to clear error

 

WX

 

 

 

 

 

 

 

 

“E:SH”

Dryer

- Shorted temperature sensor error

- Bad sensor or wiring

Cycle power to clear error

 

WX

 

 

 

 

 

 

 

 

“E:dL”

Frontload

- Door lock error

- Unable to lock or unlock the

Error cleared when door lock

 

WX

 

loading door

condition is corrected

 

 

 

 

 

“E:dO”

Frontload

- Door open error

- Door opened during a

Cycle power to clear error

 

WX

 

running cycle

 

 

 

 

 

 

“E:Ub”

Frontload

- Unbalance error

- Unable to balance a load

Error cleared after EOC (FL)

 

WX

 

 

Error cleared after 1 min.

 

 

 

 

(WX)

“E:dF”

WX

- Motor failure error

- Motor failure

Cycle power to clear error

“E:HT”

WX

- Heater error

- Maximum heat time

Cycle power to clear error

 

 

 

exceeded

 

“E:Pr”

WX

- Pressure switch sequence error

- Pressure switches out of

Cycle power to clear error

 

 

 

sequence

 

16

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

505942