Troubleshooting
Error Codes (continued)
Display | Machine | Error Description | Error Cause | Error Condition Exit |
:30 |
| - Timeout waiting for Biberon | - Bad firmware in reader |
|
|
| insertion |
|
|
:31 |
| - Hotlisted card inserted into the | - Card hotlisted | After control destroys card, the |
|
| reader |
| error is cleared |
:50 |
| - Loyalty purse read error | - Bad card |
|
:56 |
| - Loyalty purse write error | - Bad card |
|
|
|
|
|
|
Right- | All | - Network communication error | - Communication problem | Error ends at good |
most |
|
|
| communication |
dp lit |
|
|
|
|
|
|
|
|
|
“Err” | All | - Coin error | - Invalid coin pulse(s) | Error ends after several |
|
|
|
| seconds |
“Alrm” | All | - Breakin alarm error | - Service door or coin vault | Error ends after several |
|
|
| switches | seconds |
“OFF” | All | - Breakin alarm shutdown error | - Service door or coin vault | Cycle power to clear error |
|
|
| switches |
|
“E:FL” | Topload | - Fill error | - Maximum fill time exceeded | Cycle power to clear error |
| Frontload |
|
|
|
| WX |
|
|
|
|
|
|
|
|
“E:dr” | Topload | - Drain error | - Maximum drain time | Cycle power to clear error |
| WX |
| exceeded or water sensed at |
|
|
|
| end of a spin step |
|
“E:SP” | Frontload | - SPI communications error | - Internal communication | Cycle power to clear error |
| WX |
| problem |
|
|
|
|
|
|
“E:OP” | Dryer | - Open temperature sensor error | - Bad sensor or wiring | Cycle power to clear error |
| WX |
|
|
|
|
|
|
|
|
“E:SH” | Dryer | - Shorted temperature sensor error | - Bad sensor or wiring | Cycle power to clear error |
| WX |
|
|
|
|
|
|
|
|
“E:dL” | Frontload | - Door lock error | - Unable to lock or unlock the | Error cleared when door lock |
| WX |
| loading door | condition is corrected |
|
|
|
|
|
“E:dO” | Frontload | - Door open error | - Door opened during a | Cycle power to clear error |
| WX |
| running cycle |
|
|
|
|
|
|
“E:Ub” | Frontload | - Unbalance error | - Unable to balance a load | Error cleared after EOC (FL) |
| WX |
|
| Error cleared after 1 min. |
|
|
|
| (WX) |
“E:dF” | WX | - Motor failure error | - Motor failure | Cycle power to clear error |
“E:HT” | WX | - Heater error | - Maximum heat time | Cycle power to clear error |
|
|
| exceeded |
|
“E:Pr” | WX | - Pressure switch sequence error | - Pressure switches out of | Cycle power to clear error |
|
|
| sequence |
|
16 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 505942 |