WARNING
The washer-extractor should be connected to an individual branch
circuit not shared with lighting or other equipment.
4
Electrical Speciî‚¿cations WF400, IWF400, IWF090400 liters / 90 pounds
Boiler Fed/Steam Heat Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load Amps
Recommended Circuit
Breaker (US-market)
AWG/mm2
kW Standard
Heating Elements
Full Load Amps
Recommended
Circuit Breaker (US-
market)
AWG/mm2
US NON-US US NON-US
N 440-480 50/60 3 3+PE 8 15 16 14/2.5 6x4 kW 42 50 50 8/10.0
P 380-415 50/60 3 3+N+PE 25 30 32 10/6.0 60 70 70 4/25.0
Q200-240 50/60 3 3+PE 25 30 32 10/6.0 6x3 kW 70 80 80 4/25.0
X 200-240 50/60 1/3 2/3+PE 25 30 32 10/6.0 N/A N/A N/A N/A
Alternative Electric Heat Options
N 440-480 50/60 3 3+PE
3x3 kW +
3x4 kW
38 50 50 8/10.0
P 380-415 50/60 3 3+N+PE 55 60 60 6/16.0
Q200-240 50/60 3 3+PE N/A N/A N/A N/A
X 200-240 50/60 1/3 2/3+PE N/A N/A N/A N/A