Allied Air Enterprises 4PGE Connection Diagram, Single Phase - Variable Speed Motor P/N, Issue

Models: 4PGE

1 16
Download 16 pages 26.31 Kb
Page 16
Image 16
Issue 1008

Page 16

HIGH PRESSURE

SWITCH

(IF USED)

YEL

BLU

THERMOSTAT

Y G W1 R C S1

S4

IGNITION CONTROL

YEL

BLU

YEL

GRN

WHT

RED

Issue 1008

Figure 12

 

 

 

 

 

A3

CMB

L1

 

 

 

 

 

BLWR

 

 

 

 

 

 

L1

 

 

 

 

SPARK

 

 

 

 

 

 

E1

 

 

 

 

 

 

 

 

 

L1

 

K1-1

 

 

BLK

BLK

COMPRESSOR

 

 

CONTACTOR

BLK

 

 

T1

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

DUAL

 

 

 

 

 

 

 

 

 

A132

 

 

CAPACITOR

 

 

 

 

C12

 

BRN

 

 

208/230V-1-60

 

 

F

 

 

C

 

S

 

B6

 

 

 

 

COMB.

 

B1

R

 

 

C

PUR

 

 

 

BLOWER

 

 

 

 

 

 

 

AIR

 

COMPRESSOR

 

 

YEL

 

 

 

 

A132

 

 

 

H

 

 

 

 

RED

 

 

 

 

 

 

 

RED

B4

 

 

 

T2

 

 

 

 

 

 

 

 

COMPRESSOR

 

 

 

 

BLK

WHT

CONTACTOR

 

 

 

CONDENSER

K1-2

L2

 

 

 

 

 

 

FAN MOTOR

 

 

 

 

 

 

 

 

 

L2

NOTE:

IF ANY OF THE ORIGINAL WIRE IS REPLACED, THE SAME SIZE AND TYPE WIRE MUST BE USED. USE COPPER CONDUCTOR ONLY, MIN. 75°C WIRE.

WARNING-

ELECTRIC SHOCK HAZARD. UNIT MUST BE GROUNDED IN ACCORDANCE WITH NATIONAL AND LOCAL CODES.

HEAT ANTICIPATION SETTING: 0.70 AMP

LINE VOLTAGE FIELD INSTALLED

 

BLK

RED

 

 

A3

 

IGNITION CONTROL

 

 

 

 

 

 

BLK

 

 

RED

 

24VAC

 

 

 

R

 

 

 

 

 

 

 

FUSE

 

G

208V

240V

 

 

 

 

GROUND

 

 

GRN

 

 

 

C

 

 

 

 

LED

 

 

 

 

 

24V BLU

 

 

 

 

 

 

 

W

B3

 

 

 

1

6

2

5

4

3

FLAME

 

 

 

 

 

 

 

 

 

 

 

Y

TRANSFORMER

 

 

 

 

 

 

 

 

 

 

5

 

T1

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

GRY

3

 

 

 

 

BRN

ORN

PUR

PUR

RED

BLU

INDOOR

 

 

MAIN

 

 

 

 

 

 

 

 

 

 

 

LIMIT

 

 

 

 

 

 

 

BLOWER

 

 

 

S10

 

 

 

 

FLAME SENSE

WHT

BLU

SWITCH

WHT

 

 

 

 

MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROLLOUT

S47

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

PRESSURE SWITCH

ORN

 

 

 

 

 

 

 

 

 

PUR

 

 

 

 

GAS

 

 

 

 

 

 

S18

 

 

 

 

 

 

 

 

 

 

 

S21

 

 

VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

AUX. LIMIT SWITCH

GV1

 

 

 

 

 

(IF USED)

 

 

 

DIAGNOSTICS

The following ignition control board LED codes will indicate normal or abnormal operations:

SLOW FLASH Normal operation, no call for heat. FAST FLASH Normal operation, call for heat.

2 FLASH System lockout.

3 FLASH Pressure switch senses incorrect pressure.

4 FLASH Main limit open or rollout switch open.

5 FLASH Flame sensed and gas valve not energized. STEADY Internal failure (micro-controller failure; self check).

 

 

 

CONTACTOR

 

A132

 

 

 

 

 

 

 

 

YEL

Y

DIAGNOSTIC MODULE

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL

 

 

 

BLU

C

 

 

 

 

 

 

 

 

 

 

 

 

 

K1

 

 

RED

R

 

 

 

YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HUM

 

 

 

A54

 

 

RED

 

R

 

ICM BOARD

 

 

 

BLU

 

C1

 

 

 

 

SEE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EM

BLOWER SPEED

 

 

 

 

 

 

 

CHART

 

 

 

 

 

W1

 

 

 

 

 

 

 

 

ADJUST HEAT COOL

 

 

 

GRN YEL

O

 

 

 

 

 

NORM

 

A

A

 

 

 

 

Y2

 

(+)

 

B

B

 

 

 

 

 

(-)

 

C

C

 

 

 

 

Y1

 

(TEST)

 

D

D

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

G 1 2 3 4

 

 

 

 

 

 

 

ORN

 

5 6

7 8 9 10111213141516

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4 5

6 7 8 9 10111213141516

 

 

 

 

 

INDOOR BLOWER

 

 

 

 

 

 

 

MOTOR

 

B3

 

 

 

Blower Speed Chart

 

 

 

 

Unit

 

 

Fact ory Shipped Set t ings

Cooling

Heat ing

ADJUST

 

HEAT

 

COOL

Input

Input

 

 

 

 

 

 

 

 

 

 

 

 

24

68

NORM

 

 

 

A

 

 

B

30

68

NORM

 

 

 

A

 

 

A

36

68

NORM

 

 

 

B

 

 

A

36

90

NORM

 

 

 

A

 

 

A

42

83

NORM

 

 

 

C

 

 

C

42

110

NORM

 

 

 

C

 

 

C

48

83

NORM

 

 

 

C

 

 

B

48

110

NORM

 

 

 

C

 

 

B

48

138

NORM

 

 

 

A

 

 

B

506488-01

Connection Diagram

Single Phase – Variable Speed Motor

P/N 48107-001

60

83

NORM

C

A

 

 

 

 

 

60

110

NORM

C

A

 

 

 

 

 

60

138

NORM

A

A

Page 16
Image 16
Allied Air Enterprises 4PGE manual Connection Diagram, Single Phase - Variable Speed Motor P/N, Issue