Patch Release Note

PCR: 01213

Module: TRG, SNMP

Network affecting: No

The Trigger Facility was generating a trap with variable { 0 0 }, and was not documented in the ATI enterprise MIB. This issue has been resolved. The MIB object triggerLastTriggerActivated ({ enterprises(1) alliedTelesyn(207) mibObjects(8) brouterMib(4) atrouter(4) modules(4) trigger(53) 1 }) has been defined, to record the trigger number of the last trigger activated, and this variable is now transmitted in the trigger activation trap triggerTrap.

PCR: 01214

Module: SWI

Network affecting: No

In a Rapier G6, fitted with a fibre uplink module with all ports active, switching traffic between port 1 and the uplink caused the traffic flow to cease after a period of time depending on the volume of traffic. This issue has been resolved.

PCR: 01216

Module: STP

Network affecting: No

The Rapier did not include the message age of the received BDPU message in the message age of the BDPU it transmitted. Also, the message age of the message transmitted BDPU could be less than that of the received BDPU, which contravenes IEEE 802.3d. This issue has been resolved.

PCR: 01219

Module: VLAN,SWI

Network affecting: No

Reception of incorrectly tagged packets was causing corruption of the ARL table, eventually causing the switch to lock up. This issue has been resolved. Tagged packets with invalid VLAN identifiers are now discarded. The INFILTERING parameter of the SET SWITCH PORT command now defaults to ON.

PCR: 01221

Module: SWI

Network affecting: No

Flow control performance has been improved.

 

PCR: 01225

Module: IPSEC

Network affecting: No

The IPsec SA ID now wraps correctly at the 16 bit (ID = 65535) boundary.

The ID is also checked to verify that it is free before it is used.

PCR: 01227

Module: PPP

Network affecting: No

If PPPoE AC services were not deleted in the same order they were added, the DELETE command would return an “ operation successful” message but the service would still appear in the output of the SHOW PPP PPPOE command. This issued has been resolved.

PCR: 01229

Module: SWI

Network affecting: No

The CREATE CONFIG command did not include all required L3FILTER parameters in the generated script file.

PCR: 01232

Module: SWI

Network affecting: No

The L3 table on the Rapier G6 is now cleared when a switch port goes down to ensure the L3 and ARP tables are consistent.