Patch 86241-02 For Rapier Switches and AR800 Series Modular Switching Routers

5

PCR: 02321

Module: FR

Network affecting: No

A fatal error occurred when the command SET FR=0 LMI= was executed if the LMI was already set to ANNEXA, ANNEXB or ANNEXD. This issue has been resolved.

PCR: 02326

Module: IPv6

Network affecting: No

A fatal error occurred when a PING was executed over an IPV6 tunnel that had previously been deleted. Also, packet forwarding with link-local addresses was not working correctly. These issues have been resolved.

PCR: 02327

Module: IPG/FIREWALL

Network affecting: No

In some situations, multihomed interfaces caused the Firewall to apply NAT and rules incorrectly when packets were received from a subnet that was not attached to the receiving interface. This issue has been resolved.

PCR: 02328

Module: BGP

Network affecting: No

BGP was not sending a withdraw message to a peer for a withdrawn or replaced route when the new best route came from that peer. This issue has been resolved.

PCR: 02330

Module: IPv6

Network affecting: No

A buffer leak was occurring in IPv6 fragmentation. This issue has been resolved.

PCR: 02331

Module: IPG, ETH

Network affecting: No

IP is now informed when an Ethernet interface goes up or down, after a 2.5 second delay.

PCR: 02332

Module: IPSEC

Network affecting: No

The sequence number extracted from the AH and ESP header was in the wrong endian mode, which caused an FTP error with IPSEC anti-replay. This issue has been resolved.

PCR: 02334

Module: FIREWALL

Network affecting: No

It is now possible to set the domain name of the SMTP server to none (0.0.0.0) with the SET FIREWALL POLICY SMTPDOMAIN command, even if a server name has not previously been specified.

PCR: 02335

Module: CLASSIFIER

Network affecting: No

The SHOW CLASSIFIER command was not displaying Layer 3 information if the classifier had been created with the parameters ETHFORMAT=SNAP and PROTOCOL={IP0000000800}. This issue has been resolved.

PCR: 02343

Module: PPP

Network affecting: No

When acting as a PPPoE Access Concentrator (AC), if a PPPoE client sent discovery packets without the "host-unique" tag, the discovery packets sent by the AC were corrupted. This issue has been resolved.

Patch 86241-02 for Software Release 2.4.1 C613-10340-00 REV B

Page 5
Image 5
Allied Telesis 86241-02 manual PCR Module FR Network affecting No, PCR Module IPG/FIREWALL Network affecting No