D: AUXILIARY EQUIPMENT

INSTALLATION OF DELUXE WALL STATION

The Allstar Plus Deluxe Wall Station is an optional accessory designed to work with any Allstar 3000 Series Operator. Connection to any other operator may damage the operator and/or Wall Station. Only connect one operator to each Wall Station. Do not connect more than one Wall Station to an Operator.

STEP 1: After determining a suitable location, usually near the access door And at least 5 feet above the floor to prevent use by children, use the Wall Station as a guide to mark the mounting holes. Drill holes for drywall anchors or screws. NOTE: Do not mount directly to masonry walls. Use backer board.

STEP 2: A length of 4-conductor, #22 gauge wire is required to connect the Wall Station to the garage door operator. Strip approximately 6” of the wire jacket from one end and 1/2” of insulation from each wire. Carefully connect one wire to each of the four terminals indicated, noting which color is connected to which terminal. Tighten screws, being careful that no wires are allowed to touch any other terminal or any other conductive part of the circuit board. Do not overtighten the terminal screws.

104389

MOUNTING

HOLES

BACK

FRONT

4-CONDUCTOR

22 GAUGE WIRE

STEP 3: Push the wire jacket into one of the four notches provided at the ends of the housing, allowing a maximum of 1/8” inch of the jacket inside the case (too much will make mounting difficult). Carefully tuck the loose wires into the case and mount the unit using the screws provided.

STEP 4: Run the wire from the Wall Station to the operator, supporting it at 18” intervals with suitable staples. Leave a sufficient length to make the necessary connections to the operator terminal strip.

WARNING: SOME LOCAL BUILDING CODES DO NOT ALLOW SURFACE WIRING. BE SAFE AND

CHECK WITH YOUR LOCAL BUILDING INSPECTOR FIRST.

STEP 5: Disconnect the power from the operator. Strip approximately 8” of jacket from the end of the wire and 1/2” insulation from each wire. Connect to terminals 0, 1, 4 and 5 as shown in the illustration above. Support the wire near the operator with wire ties.

STEP 6: Reconnect power to the operator and test the Deluxe Wall Station functions as described in the Operation and Adjustment Instructions.

E: OPERATING PARAMETERS

Please note the following Operating Parameters which apply to Openers with Auxiliary Entrapment Protection System connected. (All-Clear Photosystem, Installation Instructions on Page 13.)

IF THE DOOR IS...

...FULLY OPEN, then pushing the standard wall Push Button will cause the door to begin MOVING DOWNWARD.

...FULLY CLOSED, then pushing the wall Push Button will cause the door to begin MOVING UPWARD.

...STOPPED, PARTIALLY OPEN, then pushing the wall Push Button will cause the door to begin MOVING UPWARD.

...MOVING UPWARD, then pushing the wall Push Button will cause the door to STOP.

...MOVING DOWNWARD, then pushing the wall Push Button will cause the door to STOP, PAUSE FOR APPROXIMATELY

ONE SECOND, AND THEN BEGIN MOVING UPWARD.

16

Page 16
Image 16
Allstar Products Group J3500, 3000 Operating Parameters, Check with Your Local Building Inspector First, If the Door is