8.2 LED IS NOT GREEN

DISTRIBUTION AMPLIFIERS

8.2 LED IS NOT GREEN

Cause 1: There is no power.

Solution: Disconnect the video input from the DA1957CT and verify the LED is on and red indicating power is present. Reconnect the computer's video output. If the LED is still not green, see Cause 2.

Cause 2: There is no sync signal.

Solution 1: Verify the computer output is operating correctly by connecting it directly to a local monitor. If the display is good, see Solution 2.

Solution 2: Verify that the transmitter and receiver are each operating correctly by connecting them directly to each other, bypassing the DA1957CT. If the display is good, see Solution 3.

Solution 3: Reconnect the DA1957CT. If the Power/Signal Present LED is on and red with a signal, call ALTINEX at

(714)990-2300.

8.3NO SOUND

Cause 1: The source has a problem.

Solution: Check the source and make sure that there is a signal present and all source connections are correct. If the source is working and there is still no sound, see Cause 2.

Cause 2: The volume is too low.

Solution: Increase the Audio Gain on the transmitter toward maximum. If there is still no sound present, see Cause 3.

Cause 3: Cable connections are incorrect.

Solution: Make sure that cables are properly connected. Also, make sure that the continuity and wiring are good. If there is still no sound, see Cause 4.

Cause 4: The receiving device is bad.

Solution: Make sure the receiving device has power and is turned on. If there is still no sound, please call ALTINEX at (714) 990-2300.

8.4 NO REMOTE IMAGE

Cause 1: The source has a problem.

Solution: Check the image on the local monitor and verify the quality is good. If the local image is good, see Cause 2.

Cause 2: Video equalization is required.

Solution: Adjust the Video Equalization on the DA1957CT. Long cable runs may require adjustment. In general, cable runs less then 50 ft (15 m) require little or no video equalization and should be set to minimum. If there is still no image, see Cause 3.

Cause 3: There is no signal.

Solution: If the Power/Signal Present LED is on and green and there is still no

image, call ALTINEX at

(714)990-2300.

8.5REMOTE IMAGE QUALITY IS POOR Cause 1: The source has a problem.

Solution: Check the image on a local monitor and verify the quality is good. If the local image is good, see Cause 2.

Cause 2: Video equalization is required.

Solution: Adjust the Video Equalization on the DA1957CT. If the image is still not

correct, call ALTINEX at (714) 990-2300.