Alto-Shaam EC2SYS-72/PR manual C Au Tio N, In Stal Lation, Dan Ger, Sit E Inst Allation, Leveling

Models: EC2SYS-96/PL EC2SYS-48/P EC2-96/PR EC2-72/PL EC2-72/PR EC2SYS-72/PR EC2SYS-72/PL EC2-96/PL EC2SYS-96/PR EC2-48/P

1 33
Download 33 pages 22.65 Kb
Page 4
Image 4
IMPROPER INSTALLATION,

DAN GER

IMPROPER INSTALLATION,

ALTERATION, ADJUSTMENT, SERVICE, OR MAINTENANCE COULD RESULT IN SEVERE INJURY,DEATH OR CAUSE PROPERTY DAMAGE.

READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.

IN STAL LATION

C AU TIO N

METAL PARTS OF THIS EQUIPMENT BECOME EXTREMELYHOT WHEN IN OPERATION. TO AVOID BURNS, ALWAYS USE HAND PROTECTION WHEN OPERATINGTHIS APPLIANCE.

C AU TIO N

TO PREVENT PERSONAL INJURY,USE CAUTION WHEN MOVING ORLEVELING THIS APPLIANCE.

SIT E INST ALLATION

In order to main tain establ ishe d Nationa l

Sanitation Found ation standa rds, all

stati ona ry floor models

must be sealed to the floor with a R.T.V. or

silas tic meeting N.S.F.

requ irements or have 6" (152m m)

unobs tru cted clea ran ce ben eath the unit.

1. The appliance must

be insta lled on a

sta ble and level sur face.

2. DO NOT install this applian ce in any area where it may be affected by any adverse conditions such as steam, grease, drippin g water, high temperatures, or any other severely adverse conditions.

3. DO NOT install a heated displa y case near a cold air source such as a freezer, air conditioning vents, or in any area where outside air fluctuation can

4. affect performance.

This applianc e must be kep t fre e and clear of any obstr uction s blo ckin g acces s for maintenance or service.

MINIMUM CLEARANCE REQUIREMENTS Coun ter and tab le units mus t be mount ed on legs of a sufficient 6" (152mm) heigh t to provide minimum unobs tructed spa ce ben eat h the uni t. These legs are supplied wit h the unit. Warranty wil l bec ome null and void if these direct ions are not foll owed .

A number of adjustments are associ ate d with initial installation and start-up. It is important that these adjust ments be conduct ed by a qualifi ed serv ice technicia n. Instal lati on and start- up adjust ments are the responsib ility of the dealer or use r. These adjust ments include but are not limited to thermost at calibration, door

adju stment, leveling, electr ica l hook -up and installation of option al casters or legs.

LEVELING

Level the appliance from side-

front-to -back with the use of a spirit level.

We recomm end checking the level periodi call y to make cert ain the floo r has not shift ed nor the appliance moved.

Failure to properly level this appliance NOTE: can cause improper function .

EC2 & EC2S YS Seri es Oper ati on & Care Manual • 3