Thermostats:

PRODUCT DESIGN

Thermostats:

The following Amana® brand Thermostats are suggested for use with the AMH8 Furnace Models:

THERMOSTATS

Thermostat

Mech./Digital

Programmable THERMOSTATS Cool Filters: Heat

CHT-18-60

Mechanical

Yes

Yes

Yes

 

 

 

 

 

CH70TG

Digital

No

Yes

Yes

 

 

 

 

 

CHSATG

Mechanical

Yes

Yes

Yes

 

 

 

 

 

H20TWR

Mechanical

Yes

No

Yes

 

 

 

 

 

Filters:

Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty.

Upflow Filters

Side Return(s)

 

Cabinet

Nominal

Approx.

 

 

Width

Filter Size

Flow Area

 

 

(in.)

(in.)

(in2)

 

 

 

 

 

 

 

All

16 x 25 x 1

400

 

 

 

 

 

 

Bottom Return

Cabinet

Nominal

Approx.

Width

Filter Size

Flow Area

(in.)

(in.)

(in2)

 

 

 

14

12 x 25 x 1

300

17-1/2

14 x 25 x 1

350

21

16 x 25 x 1

400

24-1/2

20 x 25 x 1

500

Refer to Minimum Filter Area tables to determine filter area requirement. NOTE: Filters can also be installed elsewhere in the duct system such as a central return.

MINIMUM FILTER SIZES

FURNACE INPUT

FILTER SIZE

TYPE

45M

160 in2

permanent

70M

241 in2

permanent

90M

320 in2

permanent

115M

400 in2

permanent

140M

370 in2

permanent

45M

320 in2

disposable

70M

483 in2

disposable

90M

640 in2

disposable

115M

800 in2

disposable

140M

738 in2

disposable

PERMANENT NOMINAL 600 F.M. FACE VELOCITY

DISPOSABLE NOMINAL 300 F.M. FACE VELOCITY