Amana AMH* service manual Furnace Specifications

Models: AMH*

1 17
Download 17 pages 14.76 Kb
Page 12
Image 12

FURNACE SPECIFICATIONS

MODEL

AMH80453AX**

AMH80703AX**

AMH80704BX**

AMH80903BX**

AMH80904BX**

AMH80905CX**

AMH81155CX**

AMH81405DX**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input, Natural Gas (BTUH)

45,000

70,000

70,000

90,000

90,000

90,000

115,000

140,000

 

Output, Natural Gas (BTUH) 1

36,000

56,000

56,000

72,000

72,000

72,000

92,000

112,000

 

Output, LP (BTUH)

32,000

48,000

48,000

64,000

64,000

64,000

80,000

96,000

 

A.F.U.E.

80.0%

80.0%

80.0%

80.0%

80.0%

80.0%

80.0%

80.0%

 

 

 

 

 

 

 

 

 

 

 

Rated External Static (" w.c.)

0.20 - 0.50

0.20 - 0.50

0.20 - 0.50

0.20 - 0.50

0.20 - 0.50

0.20 - 0.50

0.20 - 0.50

0.20 - 0.50

 

Temperature Rise (°F)

25 - 55

25 -55

20 - 50

35 - 65

35 - 65

35 - 65

35 - 65

40 - 70

 

Pressure Switch Trip Point (" w.c.)

-0.70

-0.70

-0.75

-0.75

-0.75

-0.75

-0.90

-0.80

 

Blower Wheel (D" x W")

10x6

10x6

10x8

10x8

10x8

10x10

10x10

11x10

 

Blower Horsepower

1/3

1/3

1/2

1/3

1/2

1/2

1/2

3/4

 

Blower Speeds

4

4

4

4

4

4

4

4

 

Max CFM @ 0.5 E.S.P.

1280

1100

1610

1439

1738

1854

1902

2084

 

 

 

 

 

 

 

 

 

 

 

Power Supply (Volts/Hz/Ph)

115/60/1

115/60/1

115/60/1

115/60/1

115/60/1

115/60/1

115/60/1

115/60/1

 

Minimum Circuit Ampacity (MCA) 2

8.1

8.1

12.5

8.1

12.5

12.5

12.5

14.7

 

Maximum Overcurrent Device 3

15

15

15

15

15

15

15

15

 

Transformer (VA)

40

40

40

40

40

40

40

40

 

 

 

 

 

 

 

 

 

 

 

Primary Limit Setting (°F)

220

170

170

170

160

180

180

160

 

Auxiliary Limit Setting (°F)

120

120

120

120

120

120

120

120

 

Rollout Limit Setting (°F)

300

300

300

300

300

300

300

300

 

 

 

 

 

 

 

 

 

 

 

Fan Delay On Heating

30

30

30

30

30

30

30

30

 

Off Heating *

150

150

150

150

150

150

150

150

 

Fan Delay On Cooling

5

5

5

5

5

5

5

5

 

Off Cooling

45

45

45

45

45

45

45

45

 

Fan Delay On - Fan Only

0

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

Gas Supply Pressure

7 / 11

7 / 11

7 / 11

7 / 11

7 / 11

7 / 11

7 / 11

7 / 11

 

(Natural/Propane) (" w.c.)

 

 

 

 

 

 

 

 

 

 

Manifold Pressure

3.5 / 10

3.5 / 10

3.5 / 10

3.5 / 10

3.5 / 10

3.5 / 10

3.5 / 10

3.5 / 10

 

(Natural/Propane) (" w.c.)

 

 

 

 

 

 

 

 

 

 

Orifice Size (Natural/Propane)

43 / 55

43 / 55

43 / 55

43 / 55

43 / 55

43 / 55

43 / 55

43 / 55

 

Number of Burners

2

3

3

4

4

4

5

6

 

 

 

 

 

 

 

 

 

 

 

Vent Connector Diameter (inches)

4

4

4

4

4

4

4

4

 

 

 

 

 

 

 

 

 

 

 

Shipping Weight (lbs.)

115

125

136

146

146

154

154

153

 

 

 

 

 

 

 

 

 

 

 

*Off Heating - This fan delay timing is adjustable (90, 120, 150 or 180 seconds). 150 seconds as shipped.

1.These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane operation.

2.Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps. Wire sizes should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes.

3Maximum Overcurrent protections Device refers to maximum recommended fuse or circult breaker size. May use time delay fuses or HACR- type circuit breakers of the same sizes as noted.

NOTES:

1.For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altitude.

2.The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufacturers method or in accordance with the "A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times output.

12

Page 12
Image 12
Amana AMH* service manual Furnace Specifications