PRODUCT DESIGN
PRESSURE SWITCH TRIP POINTS
AND USAGE CHART
SQUARE NOSE
| TRIP POINT | ID BLOWER | |
MODEL | ID BLOWER | PRESSURE | |
PRESSURE | SWITCH | ||
| |||
| SWITCH | PART # | |
AMH80453AX** | B1370142 | ||
|
|
| |
AMH80703AX** | B1370142 | ||
|
|
| |
AMH80704BX** | B1370142 | ||
|
|
| |
AMH80903BX** | B1370142 | ||
|
|
| |
AMH80904BX** | B1370142 | ||
|
|
| |
AMH80905CX** | B1370158 | ||
|
|
| |
AMH81155CX** | B1370158 | ||
|
|
| |
AMH81405DX** | 013070159 | ||
|
|
|
PRESSURE SWITCH TRIP POINTS
AND USAGE CHART
ROUND NOSE
| TRIP POINT | ID BLOWER | |
MODEL | ID BLOWER | PRESSURE | |
PRESSURE | SWITCH | ||
| |||
| SWITCH | PART # | |
AMH80453AX** | B1370142 | ||
|
|
| |
AMH80703AX** | B1370142 | ||
|
|
| |
AMH80704BX** | B1370176 | ||
|
|
| |
AMH80903BX** | B1370179 | ||
|
|
| |
AMH80904BX** | B1370179 | ||
|
|
| |
AMH80905CX** | B1370142 | ||
|
|
| |
AMH81155CX** | B1370158 | ||
|
|
| |
AMH81405DX** | 013070142 | ||
|
|
|
For installaions in Canada, the AMH8 furnace is certified only to 4,500 ft.
* Negative pressure readings are in inches of water column (*w.c.)
PRIMARY LIMIT
Part Number | 0130F00035 | 20162906 | 20162903 | 0130F00036 |
|
|
|
|
|
Open Setting (°F) | 220 | 170 | 160 | 180 |
|
|
|
|
|
AMH80453A* | 1 | |||
AMH80703A* | 1 | |||
AMH80704B* | 1 | |||
|
|
|
|
|
AMH80903B* | 1 | |||
AMH80904B* | 1 | |||
AMH80905C* | 1 | |||
AMH81155C* | 1 | |||
AMH81405D* | 1 |
ROLLOUT LIMIT SWITCHES |
| AUXILIARY LIMIT SWITCHES | ||
Part Number | 10123529 |
| Part Number | 0130F00038 |
|
|
|
|
|
Open Setting (°F) | 300 |
| Open Setting (°F) | 120 |
AMH80453AX** | 2 |
| AMH80453A* | 1 |
AMH80703AX** | 2 |
| AMH80703A* | 1 |
AMH80704BX** | 2 |
| AMH80704B* | 1 |
AMH80903BX** | 2 |
| AMH80903B* | 1 |
AMH80904BX** | 2 |
| AMH80904B* | 1 |
AMH80905CX** | 2 |
| AMH80905C* | 1 |
AMH81155CX** | 2 |
| AMH81155C* | 1 |
AMH81405DX** | 2 |
| AMH81405D* | 1 |
8