Amana AMH* service manual Blower Performance Specifications

Models: AMH*

1 17
Download 17 pages 14.76 Kb
Page 13
Image 13
BLOWER PERFORMANCE SPECIFICATIONS

BLOWER PERFORMANCE SPECIFICATIONS

(CFM & Temperature Rise vs. External Static Pressure)

Model

Motor

Tons AC

 

 

 

EXTERNAL STATIC PRESSURE (Inches Water Column)

 

 

( HeatingAs ShippedSpeed )

at 0.5"

0.1

 

 

0.2

 

0.3

 

0.4

 

0.5

 

0.6

 

0.7

0.8

Speed

 

 

 

 

 

 

 

ESP

CFM

RISE

CFM

RISE

CFM

RISE

CFM

RISE

CFM

RISE

CFM

CFM

CFM

 

HIGH

3.0

1521

 

22

 

1466

 

23

1414

 

24

1373

 

24

1298

 

26

1243

 

1164

1075

*M(H/S)80453A***

MED

2.5

1160

 

29

 

1160

 

29

1132

 

29

1121

 

30

1082

 

31

1042

 

997

925

(MEDIUM)

MED-LO

2.0

961

 

35

 

955

 

35

948

 

35

932

 

36

913

 

37

882

 

821

803

 

LOW

1.5

781

 

43

 

785

 

42

781

 

43

773

 

43

761

 

44

745

 

716

668

 

HIGH

3.0

1422

 

36

 

1352

 

38

1307

 

40

1197

 

43

1157

 

45

1092

 

1075

983

*M(H/S)80703A***

MED

2.5

1098

 

47

 

1081

 

48

1051

 

49

1039

 

50

1021

 

51

983

 

924

868

(MEDIUM)

MED-LO

2.0

919

 

56

 

913

 

57

892

 

58

847

 

----

829

 

----

818

 

792

728

 

LOW

1.5

758

 

----

 

741

 

----

741

 

----

733

 

----

699

 

----

677

 

649

626

 

HIGH

4.0

2134

 

----

 

2100

 

25

2042

 

25

1975

 

26

1883

 

28

1786

 

1700

1601

*M(H/S)80704B***

MED

3.5

1668

 

31

 

1663

 

31

1656

 

31

1645

 

32

1616

 

32

1549

 

1492

1391

(MEDIUM)

MED-LO

3.0

1419

 

37

 

1426

 

36

1426

 

36

1432

 

36

1419

 

37

1378

 

1328

1261

 

LOW

2.5

1134

 

46

 

1145

 

45

1166

 

44

1171

 

44

1160

 

45

1144

 

1111

1071

 

HIGH

3.0

1607

 

41

 

1572

 

42

1547

 

43

1498

 

45

1448

 

46

1390

 

1302

1222

*M(H/S)80903B***

MED

2.5

1159

 

58

 

1156

 

58

1145

 

58

1127

 

59

1108

 

60

1075

 

1033

957

(MEDIUM)

MED-LO

2.0

938

 

----

 

916

 

----

916

 

----

900

 

----

889

 

----

865

 

829

785

 

LOW

1.5

785

 

----

 

766

 

----

743

 

----

730

 

----

709

 

----

683

 

666

604

 

HIGH

4.0

2051

 

----

 

1983

 

----

1895

 

35

1812

 

37

1725

 

39

1627

 

1530

1439

*M(H/S)80904B***

MED

3.5

1736

 

38

 

1708

 

39

1652

 

40

1611

 

41

1540

 

43

1475

 

1394

1307

(MEDIUM)

MED-LO

3.0

1493

 

45

 

1668

 

40

1459

 

46

1429

 

47

1389

 

48

1339

 

1274

1204

 

LOW

2.5

1200

 

56

 

1185

 

56

1180

 

56

1173

 

57

1158

 

58

1125

 

1125

1080

 

HIGH

5.0

2290

 

----

 

2229

 

----

2155

 

----

2047

 

----

1960

 

----

1837

 

1712

1584

*M(H/S)80905C***

MED

4.0

1852

 

36

 

1820

 

37

1777

 

38

1719

 

39

1641

 

41

1567

 

1469

1382

(MEDIUM)

MED-LO

3.5

1615

 

41

 

1592

 

42

1556

 

43

1516

 

44

1470

 

45

1405

 

1346

1235

 

LOW

3.0

1290

 

52

 

1285

 

52

1265

 

53

1235

 

54

1214

 

55

1174

 

1044

904

 

HIGH

5.0

2323

 

37

 

2225

 

38

2120

 

40

2040

 

42

1974

 

43

1801

 

1688

1577

*M(H/S)81155C***

MED

4.0

1858

 

46

 

1847

 

46

1799

 

47

1744

 

49

1674

 

51

1577

 

1493

1399

(MEDIUM)

MED-LO

3.5

1596

 

53

 

1587

 

54

1571

 

54

1552

 

55

1493

 

57

1397

 

1326

1217

 

LOW

3.0

1291

 

----

 

1272

 

----

1261

 

----

1257

 

----

1205

 

----

1168

 

1118

1060

 

HIGH

5.0

2469

 

42

 

2389

 

43

2300

 

45

2223

 

47

2131

 

49

2027

 

1902

1786

*M(H/S)81405D***

MED

4.0

1575

 

66

 

1558

 

67

1545

 

67

1513

 

69

1500

 

69

1419

 

1354

1271

(MEDIUM)

MED-LO

3.5

1402

 

----

 

1380

 

----

1343

 

----

1319

 

----

1296

 

----

1245

 

1183

1106

 

LOW

3.0

1200

 

----

 

1186

 

----

1161

 

----

1127

 

----

1082

 

----

1042

 

995

926

NOTES:

1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer.

2. All furnaces ship as high speed cooling. Installer must adjust blower cooling speed as needed.

3. For most jobs, about 400 CFM per ton when cooling is desirable.

4. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

5. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum external static pressure allowed when heating. The data for 0.6" w.c. to 0.8" w.c. is shown for air conditioning purposes only.

6The dashed (---) areas indicate a temperature rise not recommended for this model.

7.The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a

particular CFM, while the ESP at that CFM will be lower.

13

Page 13
Image 13
Amana AMH* service manual Blower Performance Specifications