Electrical Connection Clearance

Electrical connection must be located in the area shown. Electrical connection must not interfere with gas connection.

A

D

B

C

Gas Supply Location

Gas supply must be located in the area shown. Gas connection must not interfere with the electrical connec- tion.

A

BC

B

D

A—2 inches (Both sides)

B—19½ inches

C—12 inches

D—6 inches

Electrical Connection Clearance

Gas Connection Requirements

Before connecting this appliance to the gas supply piping system, confirm installation meets the requirements of local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-Latest Edition.

When installed in mobile housing, installation is to be in accordance with CSA standard Z241.1 gas equipped mobile housing.

The installation of appliances designed for manufactured (mobile) home installation must conform with Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or when such standard is not applicable, the Standard for Manufactured Home Installation, ANSI225.1/NFPA 501A-Latest Edition, or with local codes or the standard CAN/CSA-z240MH, “Mobile Homes”, and with local codes where applicable.

The installation of appliances is to be in accordance with CAN1-B149.1 or B149.2 installation code for gas burning appliances and equipment and/or local codes. Part 1 and/ or local codes.

A

A—26 inches

B—20 inches

C—2¼ inches

D—4 inches

Gas Supply Location

Gas Supply Pressure

!CAUTION

To avoid property damage, maximum gas supply pressure must not exceed 14" WCP.

Appliance and individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psig (3.5kPa) (14" WCP).

Appliance must be isolated from gas supply piping system by closing manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.5kPa) (14" WCP).

Gas supply pressure for checking regulator setting must be at least 1" WCP above manifold pressure shown on rating label.

7

Page 7
Image 7
Amana ARG7800 Electrical Connection Clearance, Gas Supply Location, Gas Connection Requirements, Gas Supply Pressure

ARG7800, ARG7600 specifications

The Amana ARG7600 and ARG7800 models are notable entries in the range of gas ranges from Amana, a brand well-regarded for its innovation and affordability in kitchen appliances. These two models are equipped with features and technologies that cater to both everyday cooks and culinary enthusiasts alike.

One of the standout features of the ARG7600 and ARG7800 is their powerful oven capacity. With a spacious 5.0 cubic feet, these ranges provide ample space for cooking multiple dishes simultaneously. The large oven accommodates everything from large roasts to baked goods, ensuring that you can prepare family meals or entertain guests with ease.

Both models feature the innovative True Convection technology, which enhances cooking efficiency by circulating hot air evenly throughout the oven. This results in consistent cooking temperatures and faster baking times, eliminating the need for rotation of pans and ensuring that your food is cooked perfectly every time.

The ARG7600 and ARG7800 come equipped with a variety of cooking options, including multiple burners featuring different BTU outputs. This allows for precise temperature control when simmering sauces or boiling water, catering to various culinary techniques. Both models also provide a continuous grate design across the range top, enabling easy movement of pots and pans between burners without lifting.

For those who enjoy self-cleaning appliances, the ARG7600 and ARG7800 include a self-cleaning feature that makes maintaining these ranges simpler. The self-cleaning cycle uses high temperatures to burn away residue and spills, providing a hassle-free way to keep the oven clean and functioning optimally.

Functionality is further enhanced by a digital display and intuitive controls that allow users to easily set and monitor cooking times and temperatures. Some models also feature oven light and window designs that enable visibility of cooking progress without opening the door, thereby preserving heat and ensuring optimal cooking conditions.

In terms of energy efficiency, both the ARG7600 and ARG7800 models have been designed to minimize gas consumption while maintaining high performance levels. This not only helps in reducing utility bills but also contributes to environmentally friendly cooking practices.

Overall, the Amana ARG7600 and ARG7800 gas ranges combine user-friendly features, advanced cooking technology, and a robust design that can enhance the cooking experience in any home. Whether you are a novice cook or a seasoned chef, these models provide versatility and reliability to meet a variety of culinary needs. With these ranges, Amana reaffirms its commitment to quality and function in the kitchen appliance market.