Amana ARR6400/ART6511 Minimum Clearances to Combustible Surfaces, Anti-tip Bracket Installation

Models: ARR6400/ART6511

1 28
Download 28 pages 29.37 Kb
Page 6
Image 6
Minimum Clearances to Combustible Surfaces
(Figure 3)
(Figure 2)

Minimum Clearances to Combustible Surfaces

Using dimensions, prepare cabinet opening.

Minimum clearance to rear wall is 0 inches.

Minimum clearance to a vertical right or left side wall is 0 inches.

Minimum clearance to countertop/cabinet on each side is 0 inches.

Minimum of 30 inches between top of cooking surface and bottom of an unprotected wood or metal cabinet.

Minimum of 24 inches between cooking surface and protected wood or metal cabinet above range. Cabinet bottom must be protected by at least ¼ inch thick millboard with not less than No. 28 MSG sheet steel,

.015 inch thick stainless steel, .024 inch thick aluminum, or .020 inch thick copper.

A

C Anti-tip Bracket Installation

B

D

E

A—30 inches minimum

B—30 inches unprotected/24 inches protected minimum

C—13 inches maximum D—25 inches maximum E—36 inches maximum

Figure 2

Anti-tip Bracket Installation

To reduce risk of range tipping, secure range with a properly installed anti-tip bracket.

1.Measure 31/2 inches from back wall on right and left side of cabinet cutout. Mark measurements on floor and draw a straight line connecting marks.

2.Position anti-tip bracket.

If range is installed beside cabinet(s), place anti-tip bracket with back edge on line drawn on floor and side of bracket against cabinet.

If range is not installed beside cabinet(s), position range where it will be installed. Draw a line along side of range on floor from front to back. Remove range. Place anti-tip bracket with back edge over line drawn 31/2 inches from back wall and side of bracket over line drawn along side of range on floor.

Anti-tip bracket can be installed on either right or left side.

3 1/2"

or

Figure 3

3.Mark 2 hole locations in anti-tip bracket.

4.Drill 2 holes.

If drilling into wood, use a 3/32-inch drill bit.

If drilling into concrete, use a 3/16-inch masonry drill bit and insert plastic anchors.

5.Secure bracket to floor using screws supplied. Slide range into position.

6.Remove range storage drawer or lower panel and confirm anti-tip bracket is engaged with range leveling leg.

6

Page 6
Image 6
Amana ARR6400/ART6511 owner manual Minimum Clearances to Combustible Surfaces, Anti-tip Bracket Installation