Amana DRS2462BB, DRSE663BC, DRSE663BW, DRS2663BB 62/87,21, 3266,%/&$86, Trouble Shooting, Water

Models: DRS2462BW DRS246RBC DRS2462BB DRS2462BC DRS246RBB DRSE663BB DRS2663BC DRS246RBW DRS2663BW DRS2663BB DRSE663BW DRSE663BC

1 72
Download 72 pages 26.9 Kb
Page 21
Image 21
3266,%/(￿&$86(￿

723,&￿

 

3266,%/(￿&$86(￿

 

Trouble Shooting

ICE

WATER

 

 

62/87,21￿

 

 

 

 

 

Ice maker is not producing

 

Improper water valve was installed.

 

Check water connection procedure in your Installation

ice (some models-continued)

 

 

 

Instructions. Self-piercing and 3/16” saddle valves cause low

 

 

 

water pressure and may clog the line over time. Amana is not

 

 

 

 

 

 

 

 

 

 

responsible for property damage due to improper

 

 

 

 

 

installation or water connection.

 

 

 

 

 

Unit is leaking water

 

Plastic tubing was used to complete water

 

Amana recommends using copper tubing for installation.

 

 

 

connection.

 

Plastic is less durable and can cause leakage. Amana is

 

 

 

 

 

not responsible for property damage due to improper

 

 

 

 

 

installation or water connection.

 

 

 

 

 

 

 

 

 

Improper water valve was installed.

 

Check water connection procedure in your Installation

 

 

 

 

 

Instructions. Self-piercing and 3/16” saddle valves cause low

 

 

 

 

 

water pressure and may clog the line over time. Amana is

 

 

 

 

 

not responsible for property damage due to improper

 

 

 

 

 

installation or water connection.

 

 

 

 

 

Ice forms in inlet tube to ice

 

Water pressure is low.

 

Water pressure must be between 20 to 100 pounds per

maker

 

 

 

 

square inch to function properly. A minimum pressure of 35

 

 

 

 

 

pounds per square inch is recommended for units with

 

 

 

 

 

water filters.

 

 

 

 

 

 

 

 

 

Freezer temperature is too high.

 

See the controls section in your owner’s manual for

 

 

 

 

 

assistance on how to adjust your controls. Freezer is

 

 

 

 

 

recommended to be between 0 to 2°F (-18 to –17°C).

 

 

 

 

 

Water flow is slower than

 

Water pressure is low.

 

Water pressure must be between 20 to 100 pounds per

normal

 

 

 

 

square inch to function properly. A minimum pressure of 35

 

 

 

 

 

pounds per square inch is recommended for units with

 

 

 

 

 

water filters.

 

 

 

 

 

 

 

 

 

Improper water valve was installed.

 

Check water connection procedure in your Installation

 

 

 

 

 

Instructions. Self-piercing and 3/16” saddle valves cause low

 

 

 

 

 

water pressure and and may clog the line over time.

 

 

 

 

 

Amana is not responsible for property damage due to

 

 

 

 

 

improper installation or water connection.

 

 

 

 

 

 

 

 

 

Copper or plastic tubing has kinks.

 

Turn off water supply and remove kinks. If kinks cannot be

 

 

 

 

 

removed, replace tubing.

 

 

 

Water filter is clogged or needs to be

 

Change water filter.

 

 

 

changed.

 

 

 

 

 

 

 

Dispenser water is not cold

 

Refrigerator has been recently installed

 

Allow approximately 12 hours for water in holding tank to

 

 

 

 

 

chill.

 

 

 

Water supply in holding tank has been

 

 

 

 

 

 

 

 

 

depleted.

 

 

 

 

 

 

 

 

 

 

 

Water has settle into water lines outside

 

Discard first glass of water and refill.

 

 

 

holding tank and has warmed to room

 

 

 

 

 

temperature.

 

 

 

 

 

 

 

 

21

Page 21
Image 21
Amana DRS2462BB, DRSE663BC, DRSE663BW, DRS2663BB, DRS2663BW, DRS246RBW manual 62/87,21, 3266,%/&$86, Trouble Shooting, Water