GENERAL INFORMATION

TO THE INSTALLER

Before installing this unit please read this manual and the Product Data Book applicable to your model* to familiarize yourself on the specific items which must be adhered to such as maximum external static pressure to unit, air temperature rise, minimum or maximum CFM and motor speed connections.

TO THE OWNER

It is important to complete the owner registration card and mail it immediately. This will assist us in contacting you if any service or warranty information should change in the future. When completing the registration card, be sure to include the Model, Manufacturing and Serial Numbers, plus the installation date.

The warranty certificate is also supplied with the unit. Read the war- ranty carefully and note what is covered. Keep the warranty certifi- cate in a safe place so you can find it if necessary.

If additional operating instructions are required, call the dealer where the purchase was made. Keep this literature in a safe place for fu- ture reference.

UNIT PLACEMENT

WARNING

TO PREVENT POSSIBLE EQUIPMENT DAMAGE, PROPERTY DAMAGE, PERSONAL INJURY OR DEATH, THE FOLLOWING BULLET POINTS MUST BE OBSERVED WHEN INSTALLING THE UNIT.

ALL INSTALLATIONS:

Ground Level Installations Only:

When the unit is installed on the ground adjacent to the building, a level concrete (or equal) base is recommended. Prepare a base the same physical size as the unit or slightly larger and 3 inches thick.

The base should also be located where no runoff of water from higher ground can collect in the unit.

Rooftop Installations Only:

To avoid possible personal injury or property damage, the roof must have sufficient structural strength to carry the weight of the unit(s) and snow or water loads as required by local codes.

If horizontal air delivery is used, the unit may be installed directly on wood floors or on Class A, Class B, or Class C roof covering material.

To avoid possible personal injury, a safe, flat surface for service personnel must be provided.

If vertical air discharge is used and the unit is installed on combustible flooring or class A, B, or C roofing material, then the Amana® brand roof curb (PRC06A1 or PRC08A1) is required.

This unit is approved only for an outdoor installation. To assure that your unit operates safely and efficiently, it must be installed, operated, and maintained in accordance with these installation and operating instructions, all local building codes and ordinances.

The heating and cooling capacities of the unit should be greater than or equal to the design heating and cooling loads of the area to be

conditioned. The loads should be calculated by an approved method or in accordance with A.S.H.R.A.E. Guide or Manual J - Load Cal- culations published by the Air Conditioning Contractors of America. Obtain from:

American National Standards Institute

1430 Broadway

New York, NY 10018

TRANSPORTATION DAMAGE

All units are securely packed in shipping containers tested accord- ing to International Safe Transit Association specifications. The car- ton should be checked upon arrival for external damage. If damage is found, a request for inspection by carrier agent should be made in writing immediately.

The unit should be carefully inspected upon arrival for damage and bolts or screws which may have loosened in transit. In the event of damage, the consignee should:

1.Make notation on delivery receipt of any visible damage to shipment or container.

2.Notify carrier promptly and request an inspection.

3.In case of concealed damage, carrier should be notified as soon as possible-preferably within 5 days.

4.File the claim with the following supporting documents within the 9 month statute of limitations.

a.Original Bill of Lading, certified copy, or indemnity bond.

b.Original paid freight bill or indemnity in lieu thereof.

c.Original invoice or certified copy thereof, showing trade and other discounts or reductions.

d.Copy of the inspection report issued by carrier representative at the time damage is reported to the carrier. The carrier is responsible for making prompt inspection of damage and for a thorough investigation of each claim. The distributor or manufacturer will not accept claims from dealers for transportation damage.

NOTE: When inspecting the unit for transportation damage, remove all packaging materials. Recycle or dispose of the packaging mate- rial according to local codes.

RIGGING AND HANDLING

WARNING

TO PREVENT PROPERTY DAMAGE, THE UNIT SHOULD REMAIN IN AN UPRIGHT POSITION DURING ALL RIGGING AND MOVING OPERATIONS. TO FACILITATE LIFTING AND MOVING WHEN A CRANE IS USED, PLACE THE UNIT IN AN ADEQUATE CABLE SLING.

IMPORTANT: If using bottom discharge with roof curb, ductwork should be attached to the curb prior to installing the unit. Ductwork dimensions are shown in Amana® brand roof curb installation instruc- tions.

Refer to the Roof Curb Installation Instructions for proper curb in- stallation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual.

NOTE: Lower unit carefully onto roof mounting curb. While rigging unit, center of gravity may cause condenser end to be lower than supply air end.

*NOTE: Please contact your distributor or our website for the applicable product data book referred to in this manual.

3

Page 3
Image 3
Amana PACKAGE HEAT PUMP General Information, Rigging and Handling, Ground Level Installations Only

PACKAGE HEAT PUMP specifications

The Amana Package Heat Pump is a versatile and efficient heating and cooling solution designed for residential and commercial applications. Combining both heating and cooling capabilities into one compact unit, the Amana Package Heat Pump provides year-round comfort, making it a popular choice for various climates.

One of the main features of the Amana Package Heat Pump is its high energy efficiency. Many models come with a SEER rating of up to 15 or higher, ensuring that users can enjoy effective climate control while minimizing energy costs. The unit’s efficient design helps reduce electricity consumption, which is not only beneficial for the environment but also for homeowners looking to cut down on utility bills.

The Amana Package Heat Pump integrates advanced technologies to optimize performance. One notable feature is its Smart Home integration, enabling users to control their heating and cooling settings remotely through smartphone apps. This feature enhances convenience and allows users to adjust their home’s climate while they are away, ensuring optimal comfort upon their return.

Another key characteristic of this heat pump is its robust construction. The unit is designed to withstand harsh weather conditions, featuring a galvanized steel cabinet that resists corrosion and rust. Some models also come with a weather-resistant outdoor coating, further enhancing durability.

The Amana Package Heat Pump also employs environmentally friendly refrigerants, contributing to a reduced carbon footprint. With a focus on sustainability, the unit is designed to meet or exceed the latest environmental regulations, allowing consumers to make eco-conscious choices.

Furthermore, the heat pump incorporates quiet operation technology, ensuring that it runs at minimal noise levels. This is particularly important in residential settings, where noise can be a significant concern. The unit operates silently, allowing homeowners to enjoy their indoor environment without disturbance.

Installation versatility is another benefit of the Amana Package Heat Pump. Its all-in-one design means that it can be easily installed on rooftops or ground-level pads, making it suitable for a variety of building layouts and space constraints.

In summary, the Amana Package Heat Pump stands out due to its high energy efficiency, advanced technologies, durable construction, eco-friendly refrigerants, quiet operation, and versatile installation options. These features make it an ideal choice for those seeking reliable heating and cooling solutions for their homes or businesses. Whether facing the heat of summer or the chill of winter, the Amana Package Heat Pump ensures comfort throughout the year.