D. Disassemble Vent Sections

D. Disassemble Vent Sections

Rotate either section (see Figure 8.7) so the seams on both pipe sections are aligned as shown in Figure 8.8.

Pull carefully to separate the pieces of pipe.

Figure 8.7 Rotate Seams for Disassembly

Figure 8.8 Align and Disassemble Vent Sections

E. Install Decorative Ceiling Components

A decorative ceiling thimble can be installed on a flat ceiling through which the vent passes. The decorative ceiling thimble is used to cover the firestop.

Seal the gap between the vent pipe and firestop using silicone with a minimum of 300ºF continuous exposure rating to prevent cold air infiltration.

Install the decorative ceiling thimble by sliding it up to the ceiling and attaching it using the provided screws.

A decorative cathedral ceiling support box can be installed on a cathedral ceiling through which the vent passes.

Use a plumb-bob to mark the center line of the venting system on the ceiling and drill a small hole through the ceiling and roof at this point. Locate the hole and mark the outline of the cathedral ceiling support box on the outside roof.

Remove shingles or other roof covering as necessary to

cut the rectangular hole for the support box. Cut the hole 1/8 in. (3 mm) larger than the support box outline.

Lower the support box through the hole in the roof until its bottom is at least 2 in. (51 mm) below the ceiling (Figure 8.9).

Level the support box both vertically and horizontally and temporarily tack it in place through the inside walls into the roof sheathing.

Use tin snips to cut the support box from the top corners down to the roof line and fold the resulting flaps to the roof. See Figure 8.10.

Nail the flaps to the roof AFTER running a bead of non hardening sealant between the flaps and the roof.

WARNING! Risk of Fire! Clean out ALL materials from inside the support box and complete the vertical vent run and termination.

LEVEL

CATHEDRAL CEILING

SUPPORT BOX

2 in. (51 mm) MIN. BELOW FINISHED CEILING

CUT HOLE 1/8 in. (3 mm)

GREATER IN SIZE THAN

PATTERN OF SUPPORT

BOX AS IT IS PROJECTED

ONTO ROOF LINE

Figure 8.9

Figure 8.10

24

Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12

Page 24
Image 24
Heat & Glo LifeStyle 2137-900 owner manual D. Disassemble Vent Sections, E. Install Decorative Ceiling Components

FAQ

How do I disassemble vent sections?

To disassemble vent sections, rotate the sections so the seams are aligned, then carefully pull to separate the pieces of pipe.

How do I install a decorative ceiling thimble?

You can install a decorative ceiling thimble by sliding it up to the ceiling and attaching it using the provided screws, while sealing the gap between the vent pipe and restop with silicone.

What is a decorative cathedral ceiling support box used for?

A decorative cathedral ceiling support box is used for a cathedral ceiling through which the vent passes. You can install it by marking the center line of the venting system, cutting a hole in the ceiling and roof, and then securing the support box in place.