Heat & Glo LifeStyle 2137-900 Top Vent - Horizontal Termination - continued, Three Elbows, H2

Models: 2137-900

1 55
Download 55 pages 24.88 Kb
Page 13
Image 13
1. Top Vent - Horizontal Termination - (continued)

1. Top Vent - Horizontal Termination - (continued)

Three Elbows

V1 Min.

 

H1 Max.

V2 Min.

H2 Max.

Elbow only

2 ft.

 

610 mm

*

= V2

1 ft.

304 mm

2 ft.

 

610 mm

*

= V2

1-1/2 ft.

457 mm

3 ft.

 

914 mm

*

= V2

2-1/2 ft.

762 mm

5 ft.

 

1.5 m

*

= V2

3-1/2 ft.

1.1 m

7 ft.

 

2.1 m

*

= V2

4-1/2 ft.

1.4 m

15 ft.

 

4.6 m

*

= 0

 

 

 

 

 

 

 

*When using V2 , H2 Max = V2. If V2 = 0, then H2 Max = 1-1/2 ft. (38 mm)

(H1 + H2 ) cannot exceed 15 ft. (4.6 m) when using appropriate V2.

H2

V2

H1

V1

Figure 5.5

Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12

13

Page 13
Image 13
Heat & Glo LifeStyle 2137-900 Top Vent - Horizontal Termination - continued, Three Elbows, H2, V1 Min, H1 Max, V2 Min

FAQ

What is the maximum termination length for the top vent-horizontal termination?

The maximum termination length for the top vent-horizontal termination is 15 ft. (4.6 m) when using the appropriate V2.

What are the guidelines for the number of elbows in the venting system?

The guidelines specify the minimum and maximum length for various numbers of elbows in the venting system, ranging from one to three elbows.

What are the requirements for H1 and H2 in the venting system?

When using V2, H2 Max = V2. If V2 = 0, then H2 Max = 1-1/2 ft. (38 mm). The combined H1 and H2 lengths cannot exceed 15 ft. (4.6 m).