D. Vent Diagrams

WARNING

Fire Risk. Explosion Risk.

Do NOT pack insulation or other combustibles between ceiling firestops.

ALWAYS maintain specified clearances around venting and firestop systems.

Install wall shield and ceiling firestops as specified.

Failure to keep insulation or other material away from vent pipe may cause fire.

1. Top Vent - Horizontal Termination

One Elbow

V1 Minimum

H1 Maximum

Elbow only

1-1/2 ft.

457 mm

 

 

1 ft.

305 mm

2-1/2 ft.

762 mm

 

1-1/2 ft.

457 mm

3-1/2 ft.

1.1 m

 

2-1/2 ft.

762 mm

5-1/2 ft.

1.7 m

V1

3-1/2 ft.

1.1 m

7-1/2 ft.

2.3 m

H1

4-1/2 ft.

1.4 m

15-1/2 ft.

4.7 m

V1

+ H1 = 39 ft. (11.9 m) Maximum

 

 

H1 = 15-1/2 ft. (4.7 m) Maximum

Figure 5.3

Two Elbows

V1 Minimum

H1 + H2 Maximum

2 - 90º elbows

Cannot do

back to back

 

 

 

 

 

 

6 in

152 mm

1 1/2 ft.

457 mm

 

 

 

 

1-1/2 ft.

457 mm

2-1/2 ft.

762 mm

2-1/2 ft.

762 mm

4-1/2 ft.

1.4 m

3-1/2 ft.

1.1 m

6-1/2 ft.

1.9 m

 

 

 

 

5-1/2 ft.

1.7 m

15-1/2 ft.

4.7 m

V1 + H1+ H2 = 48 ft. (14.6 m) Maximum H1 + H2 = 15-1/2 ft. (4.7 m) Maximum

H2

H1

V1

Figure 5.4

INSTALLED

HORIZONTALLY

12

Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12

Page 12
Image 12
Heat & Glo LifeStyle 2137-900 Vent Diagrams, Top Vent Horizontal Termination One Elbow, Two Elbows, Minimum Maximum