7 Appliance Preparation
A. Top Vent
CAUTION
Sharp Edges
•Wear protective gloves and safety glasses during installation.
ELBOW HEAT SHIELD
Figure 7.1
An elbow heat shield is attached to the Soho24B. Do not remove this heat shield.
SUPPORT TAB
ROPE RING
Figure 7.2
If venting with a 90 degree elbow directly off of the top of the unit, the heat shield should be placed as shown. Ro- tate the heat shield up to the vertical position and fold the tab down to contact the elbow. Make sure the rope ring, found in the manual bag, is in place around the elbow before attaching more pipe.
Figure 7.3
This is a view from the front of the unit when the elbow heat shield is properly in place.
ROPE RING
Figure 7.4
If venting vertically or using vertical pipe before the elbow, rotate the elbow heat shield to a vertical position and fold the heat shield in half as shown. Make sure the rope ring, found in the manual bag, is in place around the first sec-
tion of vent pipe.
Figure 7.5
This is a view from the front of the unit when not using an 90 degree elbow directly off the top of the unit.
Heat & Glo • Soho24B • | 19 |