Heat & Glo LifeStyle 2137-900 D. Junction Box Installation, Romex, Connector, Cover Plate, Copper

Models: 2137-900

1 55
Download 55 pages 24.88 Kb
Page 31
Image 31
D. Junction Box Installation

PLUG-IN

3V TRANSFORMER

ON/OFF

WALL SWITCH

IGNITION

 

MODULE

 

(3V)

 

VALVE

LOW VOLTAGE

 

SEE NOTE 1

NEUTRAL

GROUND REMOTE

 

CONTROL HOT

BLACK WIRE CAN BE

 

PLUGGED INTO ANY

 

OF #1 - #5 LOCATIONS

 

ON THE HOT SIDE

 

WHITE WIRE CAN BE

PLUGGED INTO ANY

OF#1 - #5 LOCATIONS

ON THE NEUTRAL SIDE

TRANSFORMER

3 VAC

IGNITION MODULE 3 VAC

ORG

WHT

 

GROUND TO

 

FIREPLACE

 

CHASSIS*

BLK

ORG

 

RED

BRN

BRN

VALVE

INTERMITTENT

PILOT IGNITOR

GRN

THERMOSTAT

WIRE

ASSEMBLY

PLUG-IN

RomexConnectorCover PlateCopper REMOTE GRN wireground attached JUMPER WIRE

Figure 10.1 IntelliFire Pilot Ignition (IPI) Wiring Diagram - Standard Method. Note: Appliance will not operate unless properly grounded.

D. Junction Box Installation

If the box is being wired from the OUTSIDE of the appliance:

Remove the cover plate located on the outer shell - right side (see Figure 10.2).

Install the supplied Romex™ connector in the cover plate.

Feed the necessary length of wire through the connector.

Make all necessary wire connections and reattach the cover plate to the outer shell.

If the box is being wired from the INSIDE of the appliance:

Remove the screw attaching the junction box/ receptacle to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 10.2).

Pull the electrical wires from outside the appliance through this opening into the valve compartment.

 

Romex

 

Connector

 

14/2WG

 

Cover Plate

 

outside firebox

WHT

 

BLK

 

WHT

 

BLK

Copper

 

GRN wire

ground attached

to GRN screw with

inside box

GRN wire

 

NOTE: Do NOT wire

 

110VAC to wall switch.

Figure 10.2 Junction Box Detail

Feed the necessary length of wire through the connector.

Make all necessary wire connections to the junction box/ receptacle and reassemble the junction box/receptacle to the

outer shell.

Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12

31

Page 31
Image 31
Heat & Glo LifeStyle 2137-900 D. Junction Box Installation, Romex, Connector, Cover Plate, Copper, GRN wire, inside box

FAQ

What is the standard method for wiring the IntelliFire Pilot Ignition IPI?

The standard method for wiring the IntelliFire Pilot Ignition IPI is shown in Figure 10.1.

How should I wire the junction box if it is being done from the outside of the appliance?

If the box is being wired from the outside of the appliance, follow the instructions provided in D.Junction Box Installation section.

What should I avoid when wiring the appliance?

Avoid wiring 110VAC to the wall switch. It should not be wired to the wall switch.