2.Top Vent - Vertical Termination No Elbow

V1 = 45 ft Max. (13.72 m) V1 = 3 ft Min. (914 mm)

V1

Note: The vertical termination baffle should be used for runs of 7 feet or greater. Use the vertical termination baffle for these applications:

Extended vertical vent runs

Extended vertical and horizontal vent runs with PVK-80 Power Vent.

The vertical restrictor has a break away portion that creates a larger hole. If venting 7-15 feet, the break away portion MUST be removed and the larger hole must be used. If venting over 15 feet, the break away portion should be left in place and the small hole should be used. For PVK-80 Power Vent ap- plications, the break away portion should be left in place and the small hole should be used.

Figure 5.6

BREAK AWAY PORTION

VERTICAL TERMINATION BAFFLE

Two Elbows

V1 Minimum

 

 

 

 

H1 Maximum

V2

V1 + V2

Minimum

 

One Elbow

 

 

 

1-1/2 ft.

457 mm

*

*

*

 

1/2 ft.

152 mm

 

2 ft.

610 mm

*

*

*

 

1-1/2 ft.

457 mm

 

3 ft.

914 mm

*

*

*

 

2-1/2 ft.

762 mm

 

5 ft.

1.5 m

*

*

*

 

3-1/2 ft.

1.1 m

 

 

7 ft.

2.1 m

*

*

*

 

5-1/2 ft.

1.7 m

 

 

15 ft.

4.6 m

*

*

*

 

 

 

 

V1 + V2 + H1 = 38 ft. (11.6 m) Max.

 

 

 

V2

*No specific restrictions on this value EXCEPT

 

 

V

1

+ V

2

+ H

1

cannot exceed 38 ft. (11.6 m)

 

 

 

 

 

 

 

 

 

 

 

H1

V1

Figure 5.7

14

Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12

Page 14
Image 14