10 Electrical Information
A. Recommendation for Wire
This appliance requires
NOTE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA
•A
B.Connecting to the Appliance
C. IntelliFire Ignition System Wiring
This appliance requires a 110 VAC supply to the appliance junction box for operation. A wiring diagram is shown in Figure 10.1.
This appliance is equipped with an IntelliFire control valve which operates on a 3 volt system.
This appliance is supplied with a 3 volt AC transformer which requires the installation of the supplied junction box. It is highly recommended that the junction box be installed at this time to avoid reconstruction.
CAUTION
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
•Incorrect wiring will damage millivolt valves.
•Incorrect wiring will override IPI safety lockout and may cause explosion.
WARNING
Shock hazard.
•Replace damaged wire with type 105º C rated wire.
•Wire must have high temperature insulation.
•If using thermostat use one compatible with a millivolt gas valve system.
•Follow parameters for locating thermostat (see individ- ual thermostat instructions) to ensure proper operation of appliance.
•Use low resistance thermostat wire for wiring from igni- tion system to the wall switch and thermostat.
•Keep wire lengths as short as possible by removing any excess wire length.
•Low voltage and 110 VAC voltage cannot be shared within the same wall box.
Note: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA