NV360/580 Series

Troubleshooting

Honeywell VS8420 Standing Pilot

START

Gas Supply ON

YES

Pilot Lights with Piezo Ignitor

YES

Pilot Stays Lit

YES

Pilot Lights

Main Burner

YES

Remove Glass Panel Before Servicing.

CHECK

NO

 

 

• Supply line hooked up

 

 

• Shutoff valve open

 

 

 

 

 

 

 

 

 

 

• Lockout has engaged. Wait

 

 

 

 

 

60 seconds and try again.

NO

 

 

 

• For spark at electrode while

 

 

 

depressing Piezo - 1/8" gap to

 

 

 

 

 

 

 

 

pilot hood needed.

 

 

 

 

 

• All wiring connections

 

 

 

 

 

• Replace Piezo ignitor

 

 

 

 

 

• For air in lines

 

 

 

 

 

• Thermopile needs a minimum

 

 

 

 

 

325mV. Adjust pilot flame height.

 

 

 

 

 

• All Wiring connections

NO

 

 

 

 

• Replace thermopile

 

 

 

• Thermocouple needs a minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

14mV.

Defective valve. Turn to pilot, meter should read greater than 100mV. If not, replace.

Valve is turned on

Wall switch is not turned on.

NO

 

Watch for grounded wires!

 

Thermopile needs a minimum 325mV.

Plugged burner orifice.

System OK

FP396a

16

20003565

Page 16
Image 16