NV360/580 Series
INSIDE | Electrical Box |
| |
FRONT |
|
OFUNIT |
|
OUTSIDE |
|
OF | UNIT |
|
FRONT
FP580
Fig. 7 EB-1 receptacle.
6.Connect the white wire of the power line to the chrome screw of the socket assembly.
7.Connect the ground wire of the supply line to the green screw of the socket assembly.
8.Refit the socket assembly back into the electrical box and replace the cover plate. Secure the cable with the clamp on the outside of the unit to prevent strain on the connections.
9.The
ply power to the FK12 or FK24 fan kits if fitted.
Install the Venting System,
Flashing and Termination
NOTE: The NV360 uses a 6"
Refer venting installation instructions provided by the
Refer to Page 4, Figure 1 to locate chimney centerline dimension from a combustible back wall.
•Minimum vertical chimney height — 12 feet (3.65 m). (measured from the bottom of the fireplace)
•Maximum vertical height — 40 feet (12 m).
•Minimum height with two (2) elbows — 18 feet (5 m)
•Elbow requirements allow a maximum of two (2) 90° elbows or four (4) 45° elbows per installation. (Two (2) 45° elbows = One (1) 90° elbow.) Refer to the venting chart for proper elbow offset runs.
For firestop positioning, refer to Figure 8. Only one (1) firestop required per frame. NOTE: A firestop is not required at the roof.
Attic Installation
Firestop position when area above ceiling is an attic. Nail (4)
Firestop Spacer
Joist
Ceiling Installation
Firestop position when area above ceiling is NOT an attic.
(Firestop/draftstop ap- pearances my vary. Only 1 firestop required per frame.)
FP384
Fig. 8 Firestop/draftstop positions.
8 | 20003565 |