NV360/580 Series
Turn |
|
|
|
counterclockwise | LO | HI | Turn clockwise |
to increase |
| to decrease | |
|
| ||
flame height |
|
| flame height |
|
| HV102 |
Fig. 13 Flame adjustment knob for Honeywell valve. | ||
Turn | IH | Turn clockwise |
counterclockwise |
| |
to increase |
| to decrease |
flame height | LO | flame height |
| HV116 | |
|
| |
Fig. 14 Flame adjustment knob for SIT 820 valve. | ||
3/8" - 1/2" |
| PSE Pilot |
|
| |
(10 - 13 mm) |
|
|
SIT Pilot |
|
|
|
| |
Fig. 15 Correct pilot flame appearance. |
|
Yellow Flame
LG118
Red Glow
DV580
Red Glow
Fig. 16 Correct burner flame appearance.
Inspecting the Venting System
This appliance venting system was designed and con- structed to develop a positive flow adequate to remove flue gases to the outside atmosphere.
Any foreign object in the venting system, except those designed specifically for the venting system, may cause spillage of flue gases.
To inspect the venting system, make sure the main gas valve is off. Remove glass frame (See Window Frame Assembly Removal Section). Using a flashlight, check the area above the baffle in the combustion dome.
Clean if necessary.
Test Chimney Draw
A "Chimney Draw" test must be made before the instal- lation is complete.
1.Close all doors and windows in the home and start exhaust fans in the kitchen and bathroom.
2.Light unit and operate for 5 minutes.
3.Hold an ignited match, cigarette or smoke match in front of the unit. Refer to Figure 17 for location of the draft hood opening.
4.Check to make sure smoke from the match, ciga- rette or smoke match is drawn into the fireplace. If it
DV360
Yellow
Flame
LG121
12 | 20003565 |