DX4™

Cleaning

Due to fog residue, smoke, and dust, cleaning the mixer should be carried out periodically to optimize light output.

1.Use normal glass cleaner and a soft cloth to wipe down the outside casing.

2.Use a cleaner specially designed for electronics to spray in and around the knobs and switch. This will reduce small particle built up that can effect the proper operation of the mixer.

3.Clean should be carried out every 30-60 days.

4.Always be sure to dry all parts completely before plugging the mixer in.

Cleaning frequency depends on the environment in which the mixer operates (i.e. smoke, fog residue, dust, dew).

DX4™

Cross Fader Replacement

The crossfader is “Hot Swappable” which means it may be replaced at any time, even when power is applied. Only replace with American Audio Feather Fader Plus. Replacing with any other model fader may seriously damage your mixer.

Replacing the Crossfader:

1.Using a number two Phillips screw driver, unscrew the each of the stainless steel retaining screws that hold the crossfader in place.

2.Gently remove the crossfader from its seated position. You may need to wiggle the crossfader slightly to unseat it.

3.After removing the crossfader, disconnect the ribbon cable that attaches the crossfader to the PC board. Grasp the crossfader by its base and pull the ribbon cable by its connector not the actual cables. The connector is desired to only fi t one way, so don’t worry about the connectors orientation.

4.Connect the new crossfader to the ribbon cable.

5.Reassemble in reverse order.

©American Audio® - www.americandj.com - DX4™ Instruction Manual Page 11

Page 11
Image 11
American Audio DX4 manual Replacing the Crossfader