59
SECTION IX

REVERSING TIMER SPIN/DWELL ADJUSTMENTS

Timer models have an electric reversing timer in the electric service box, which is located in the upper left rear
area of the dryer.
Both the dwell (stop) time and basket (tumbler) spin time are adjustable by mode selection switches located on
the electronic timer (as noted in the illustration below).

TIMING LEGEND

SPIN TIME
Adjustmen t P os ition N u mbe r 1 2 3 4 5
Time in Seconds* 30 60 90 120 150
DWELL (STOP) TIME
Adjustmen t P os ition N u mbe r 1 2 3 4 5
Time in Seconds* 5 6.3 7.6 8.9 10.2
* Values shown are +/- 1-second.