American Dryer Corp AD-200 service manual

Models: AD-200

1 82
Download 82 pages 45.1 Kb
Page 37
Image 37

13)Hoist the new steam coil into place and bolt down.

14)Replace ALL of the panels removed in Step #10.

15)Reinstall ALL of the piping removed from the old steam coil in Step #9.

NOTE: Thread sealant certified for steam piping must be applied to the threads.

16)Reconnect ALL of the piping (supply lines and return lines) disconnected in Step #8.

17)Reinstall steam damper cylinder (piston) removed in Step #6.

18)Reestablish electrical service to the dryer.

19)Close the 1/2" plug which was opened in Step #5.

WARNING: THE 1/2" PLUG MUST BE CLOSED BEFORE ATTEMPTING TO APPLY ANY STEAM PRESSURE.

20) Open the return line then open the supply line.

33

Page 37
Image 37
American Dryer Corp AD-200 service manual