American Dryer Corp AD-200 service manual VAC Direct Spark Ignition DSI Module

Models: AD-200

1 82
Download 82 pages 45.1 Kb
Page 16
Image 16

a. The Direct Spark Ignition (DSI) Module is a 24 VAC device designed to be the "controller" of the DSI system. When activated by the dryer controls, this module constantly monitors and controls the functions of the DSI system (i.e., spark activation, gas valve off/on, flame verification, etc.). Additionally, the DSI Module has self diagnostic capabilities.

24 VAC

Direct Spark Ignition (DSI) Module

b. The Ignitor and Flame-Probe Assembly is located in the burner flame area and is used to ignite the gas by use of a high voltage spark (approximately 14,000 volts) and to provide feedback information to the DSI Module as to whether the burner flame is evident (on).

Ignitor/Flame Probe Assembly

c. The Burner Hi-Limit Switch is a thermostat type switch located in the burner. Its function is to discontinue heat (flame) in the event of an over temperature situation (above 330º F).

MAN3484

330º F Thermostat

d.The Sail Switch Assembly is located on the burner, downstream of the flame tubes. Its function is to detect whether or not there is sufficient air flow through the dryer.

Sail Switch Assembly

12

Page 16
Image 16
American Dryer Corp AD-200 service manual VAC Direct Spark Ignition DSI Module