Manuals
/
Brands
/
Laundry Appliance
/
Clothes Dryer
/
American Dryer Corp
/
Laundry Appliance
/
Clothes Dryer
American Dryer Corp
AD-200 service manual
1
1
82
82
Download
82 pages, 1.86 Mb
ADC
Part No. 450310
American Dryer Corporation
88 Currant Road
Fall River, MA 02720-4781
Telephone: (508) 678-9000 / Fax: (508) 678-9447
e-mail: techsupport@amdry.com
062599DMG/cms
AD-200 Service Manual
with Non-Tilt Options
1993 thru 1998
Contents
Main
Retain This Manual In A Safe Place For Future Reference
Important
AD-200 Non-Tilting
Page
FOR YOUR SAFETY
IMPORTANT
Table of Contents
SECTION I
SAFETY PRECAUTIONS
Page
SECTION II
ROUTINE MAINTENANCE
A. CLEANING
Page
B. LUBRICATION
Page
SECTION III
SPECIFICATIONS and DIMENSIONS
A. SPECIFICATIONS (Gas and Steam Models)
Gas* Steam*
SECTION IV
INSTALLATION REQUIREMENTS
A. Enclosure, Air Supply and Exhaust Requirements
B. Electrical and Gas Requirements
C. Operational Service Check Procedure
SECTION V
COMPONENT DESCRIPTION
DIRECT SPARK IGNITION (DSI) SYSTEM COMPONENTS/FUNCTIONS
A. Heat Section
Page
NOTE: THE DSI GAS VALVES ARE NOT FIELD REPAIRABLE.
Page
B. Troubleshooting The Direct Spark Ignition (DSI) System
Available From ADC
MANOMETER
DSI IGNITOR GAP FEELER GAUGE (1/8")
Available From ADC MULTIMETER / VOLTMETER
Page
NOTE: Preliminary steps - DO NOT OMIT - to minimize the time required to troubleshoot this system.
Page
Page
Page
Page
Page
IMPORTANT: THE GAP SETTING ON THE IGNITOR/ FLAME-PROBE ASSEMBLY IS CRITICAL.
Page
Page
Page
C. Natural Gas To L.P. (Liquid Propane) Gas Conversion Instructions
Page
D. Steam Coil System Operation
Page
Page
Page
Page
E. Sprinkler System Description
Page
NOTE: Identify the wires removed for proper reinstallation.
Page
Page
Page
F. Air Jet Assembly
Page
Page
Page
NOTE: Make certain that the squirrel cage fan (impellor and blower) can spin freely.
IMPORTANT: DO NOT OVERTIGHTEN V-BELTS.
IMPORTANT: DO NOT OVERTIGHTEN V-BELTS.
Page
Page
G. Filter/Regulator Assembly
NOTE: THIS SELF-RELIEVING FEATURE IS NOT DESIGNED TO BLEED THE DOWN- STREAM PRESSURE
H. Door Systems
Page
Page
Page
Page
Page
I. Control Electrical System
Page
Page
SECTION VI
BASIC TROUBLESHOOTING
Page
Page
Page
Page
Page
U. Excessive noise and vibration...
SECTION VII
ELECTRICAL TROUBLESHOOTING
Page
Page
IMPORTANT: The L.E.D. indicator on the computer board that reads "DOOR" must be on in
Page
Page
Page
Page
Page
SECTION VIII
PHASE 5 OPL SYSTEM DIAGNOSTICS
Diagnostic (LED Display) Failure Codes
Phase 5 OPL Microprocessor Controller Relay Output LED Indicators
LED Display Indicators