SAFETY DEVICES | LOCATION | FUNCTION | COMPUTER | RESULT OF | |
DISPLAY MESSAGE | TRIPPING | ||||
|
|
| |||
|
|
|
|
| |
LOAD DOOR SWITCH | LEFT SIDE OF LOAD | INSURES DRYER LOAD | "DOOR OPEN" | DRYER WILL NOT RUN | |
DOOR | DOOR ARE CLOSED | ||||
|
|
| |||
|
|
|
|
| |
UNLOAD DOOR | RIGHT SIDE OF | INSURES DRYER |
|
| |
SWITCH (TWO DOOR | UNLOAD DOORS ARE | "DOOR OPEN" | DRYER WILL NOT RUN | ||
UNLOAD DOOR | |||||
UNIT ONLY) | CLOSED |
|
| ||
|
|
| |||
|
|
|
|
| |
TILTING SWITCHES | TOP LEFT SIDE OF | INSURES DRYER IS | "LEVEL FAULT" | DRYER WILL NOT RUN | |
BASE MODULE | LEVEL | ||||
|
|
| |||
|
|
|
|
| |
DRUM ROTATION | LEFT SIDE OF | INSURES TUMBLER IS | "DRUM FAULT" | STOPS HEAT ONLY | |
SENSOR | TUMBLER SECTION | ROTATING | |||
|
| ||||
|
|
|
|
| |
LINT CHAMBER AIR | CENTER OF HEAT | INSURES PROPER AIR | "AIRFLOW |
| |
FLOW THROUGH | STOPS HEAT ONLY | ||||
PRESSURE SWITCH | CONSOLE | FAULT" | |||
DRYER |
| ||||
|
|
|
| ||
|
|
|
|
| |
BURNER FAN AIR |
| INSURES PROPER |
|
| |
CENTER OF HEAT | CAOMBUSTION AIR |
|
| ||
FLOW SWITCH (GAS | "HEATER FAULT" | STOPS HEAT ONLY | |||
CONSOLE | FLOW INTO THE | ||||
DRYERS ONLY) |
|
| |||
| BURNER BOX |
|
| ||
|
|
|
| ||
|
|
|
|
| |
HI/LO GAS | LOWER LEFT OF | INSURES PROPER GAS | "GAS SUPPLY |
| |
PRESSURE SWITCH | HEAT CONSOLE | SUPPLY PRESSURE FOR | STOPS HEAT ONLY | ||
FAULT" | |||||
(GAS DRYERS ONLY) | SECTION | ADEQUATE IGNITION |
| ||
|
| ||||
|
|
|
|
| |
|
| INSURES THAT THE |
|
| |
HEAT RECLAIMER | RIGHT SIDE OF HEAT | HEAT RECLAIMER IS | INPUT LED #13 OF | NONE | |
DAMPER SWITCH | CONSOLE | EITHER OPENED OR | THE PLC IS OFF | ||
| |||||
|
| CLOSED |
|
| |
|
|
|
|
| |
HEAT CONSOLE | INSIDE HEAT | INSURES THAT ACCESS |
|
| |
DOOR ACCESS DOOR | "DOOR OPEN" | DRYER WILL NOT RUN | |||
CONSOLE | DOORS ARE CLOSED | ||||
SWITCH |
|
| |||
|
|
|
| ||
|
|
|
|
| |
EXHAUST AIR TEMP | INSIDE BURNER | MONITORS TUMBLER | "EXHAUST DSFL" | STOPS HEAT ONLY | |
CONTROL SENSOR | SECTION DUCT | EXHAUST AIR TEMP | |||
|
| ||||
|
|
|
|
| |
EXHAUST AIR HI | INSIDE EXHAUST | MONITORS TUMBLER |
|
| |
TEMP CONTROL | EXHAUST AND AIR | STOPS HEAT ONLY | |||
DUCT | |||||
SENSOR | TEMP |
|
| ||
|
|
| |||
|
|
|
|
| |
INTAKE AIR TEMP | TOP RIGHT OF | MONITORS TUMBLER |
|
| |
CONTROL SENSOR | "INTAKE DSFL" | STOPS HEAT ONLY | |||
TUMBLER SECTION | AIR INTAKE TEMP | ||||
(OPTIONAL) |
|
| |||
|
|
|
| ||
|
|
|
|
| |
INTAKE AIR TEMP | TOP RIGHT OF | MONITORS TUMBLER | STOPS HEAT ONLY | ||
CONTROL SENSOR | TUMBLER SECTION | AIR INTAKE TEMP | |||
|
| ||||
|
|
|
|
| |
BURNER | TOP OF BURNER | MONITORS AIR TEMP |
|
| |
ABOVE THE BURNER | STOPS HEAT ONLY | ||||
SAFETY SENSOR | SECTION | ||||
BOX |
|
| |||
|
|
|
| ||
|
|
|
|
| |
|
| OPEN SPRINKLER | ORANGE SPRINKLER | OPENS THE SPRINKLER | |
SPRINKLER CONTROL | TOP RIGHT OF | SYSTEM WATER VALVE | WATER VALVE AND | ||
PILOT LIGHT COMES ON. | |||||
SAFETY SENSOR | TUMBLER SECTION | ON | POWER DOWN THE | ||
ALARM HORN SOUNDS | |||||
|
| CONDITION | WHOLE DRYER | ||
|
|
| |||
|
|
|
|
| |
|
| DISABLES MACHINE |
|
| |
|
| WHEN DRAWERS ARE |
|
| |
LINT DRAWER | ABOVE LINT DRAWER | OPEN OR IF DRAWERS | LINT DRAWER | DRYER WILL NOT RUN | |
SWITCHES | HANDLES | HAVE NOT BEEN | |||
|
| ||||
|
| CLEANED IN LAST FIVE |
|
| |
|
| LOADS. |
|
| |
|
|
|
|
|
39