Frymaster 8195915 high limit trips, without heat, indicator ON, Fryer stops heating, Celsius

Models: 8195915

1 38
Download 38 pages 21.93 Kb
Page 32
Image 32
high limit trips

Problem

Probable Causes

Corrective Action

Fryer heats until

 

Call FASC.

high limit trips

Contactor or controller has failed.

 

without heat

 

 

 

indicator ON.

 

 

Fryer stops heating

 

Determining which component has

The high limit thermostat or

failed is beyond the scope of

with heat indicator

contactor has failed.

operator troubleshooting. Call

ON.

 

FASC.

 

 

6.2.2 Error Messages and Display Problems

 

Problem

Probable Causes

Corrective Action

 

 

Verify that the drain valve is fully

 

 

closed. The fryer will not function

Basket lift timer

 

if the drain valve is not fully

Open drain valve or problem with

closed. If the drain valve is fully

display shows

latching circuits

closed, the problem is within the

.

 

latching circuitry and is beyond the

 

 

 

 

scope of operator trouble shooting.

 

 

Call FASC.

 

 

This in an indication of a

Basket lift timer

Frypot temperature is more than

malfunction in the temperature

control circuitry, including a

410ºF (210ºC) or, in CE countries,

display shows .

failure of the high limit thermostat.

395ºF (202ºC).

 

Shut the fryer down immediately

 

 

 

 

and call FASC.

Basket lift timer

 

This indicates a problem within the

Problem with the temperature

temperature measuring circuitry

display shows

measuring circuitry including the

that is beyond the scope of

.

probe.

operator troubleshooting. Shut the

 

 

fryer down and call FASC.

 

 

CM III computers may be

CM III display is in

 

programmed to display in either

 

Fahrenheit or Celsius. Refer to the

wrong temperature

 

Incorrect display option programmed.

separate Frymaster Fryer

scale (Fahrenheit or

 

Controllers User's Manual for

Celsius).

 

 

instructions on changing the

 

 

 

 

display.

 

 

Verify that the drain valve is fully

 

 

closed. The fryer will not function

CM III display

 

if the drain valve is not fully

Open drain valve or problem with

closed. If the drain valve is fully

shows .

latching circuitry.

closed, the problem is within the

 

 

latching circuitry and is beyond the

 

 

scope of operator trouble shooting.

 

 

Call FASC.

6-4

Page 32
Image 32
Frymaster 8195915 high limit trips, without heat, indicator ON, Fryer stops heating, with heat indicator, display shows