6.2.3 Basket Lift Problems

Problem

Probable Causes

Corrective Action

Basket lift

 

Apply a light coating of

Lack of lubrication on basket lift

Lubriplateor similar lightweight

movement is noisy,

rods.

white grease to the rod and

jerky, or erratic.

 

bushings.

 

 

6.2.4 Filtration Problems

 

 

 

 

Problem

Probable Causes

Corrective Action

 

 

A. Verify that the power cord is

 

A. Power cord is not plugged in or

fully plugged in. If so, verify

 

circuit breaker is tripped.

that circuit breaker is not

 

 

tripped.

 

 

B. If the motor is too hot to touch

 

 

for more than a few seconds, the

 

B. Pump motor has overheated

thermal overload switch has

 

causing the thermal overload

probably tripped. Allow the

Filter pump won't

switch to trip.

motor to cool at least 45

 

minutes then press the Pump

start.

 

 

Reset Switch.

 

 

 

C. Blockage in filter pump.

C. Pump blockages are usually

 

Test: Close the drain valve and

caused by sediment buildup in

 

the pump due to improperly

 

pull the filter pan out from the

sized or installed filter paper

 

fryer. Activate the pump. If the

and failure to use the crumb

 

pump motor hums for a short time

screen. Call FASC.

 

then stops, the probable cause is

 

 

blockage of the pump itself.

 

Filter pump runs

Blockage in filter pan suction tube.

The blockage may be caused by

 

sediment buildup or, if solid

but oil does not

Test: Close the drain valve and pull

shortening is used, solidified

return to frypot and

the filter pan out from the fryer.

shortening in the tube. Use a thin,

there is no bubbling

Activate the pump. If the air or

flexible wire to remove the

oil or air coming

bubbling oil comes out of the Power

blockage. If the blockage cannot

from the Power

Shower, there is a blockage in the

be removed, call FASC.

Shower.

filter pan suction tube.

 

 

 