Frymaster 8195915 Digital controller, display is in wrong, temperature scale, Fahrenheit or

Models: 8195915

1 38
Download 38 pages 21.93 Kb
Page 34
Image 34
Digital controller

Problem

Probable Causes

Corrective Action

Digital controller

 

Digital controllers are manually set

 

to display in one temperature scale

display is in wrong

 

 

or the other. Refer to the separate

temperature scale

Incorrect display option selected.

Frymaster Fryer Controllers

(Fahrenheit or

 

 

User's Manual for instructions on

Celsius).

 

 

changing the display.

 

 

 

 

Verify that the drain valve is fully

Digital controller

 

closed. If the drain valve is fully

Open drain valve or problem with

closed, the problem is within the

display shows

latching circuits

latching circuitry and is beyond the

.

 

scope of operator trouble shooting.

 

 

 

 

Call FASC.

 

 

This in an indication of a

Digital controller

Frypot temperature is more than

malfunction in the temperature

control circuitry, including a

410°F (210°C) or, in CE countries,

display shows .

failure of the high limit thermostat.

395°F (202°C).

 

Shut the fryer down immediately

 

 

 

 

and call FASC.

Digital controller

 

This indicates a problem within the

Problem with the temperature

temperature measuring circuitry

display shows

measuring circuitry including the

that is beyond the scope of

.

probe.

operator troubleshooting. Shut the

 

 

fryer down and call FASC.

 

 

This in an indication of a

 

 

malfunction in the temperature

 

 

measuring or control circuitry,

Solid state controller

Oil temperature above acceptable

including a failure of the high limit

range or a problem with the

thermostat. Determining the

trouble light ON.

temperature measuring circuitry.

specific problem is beyond the

 

 

 

scope of operator troubleshooting.

 

 

Shut the fryer down immediately

 

 

and call FASC.

 

 

Verify that the drain valve is fully

Solid state controller

 

closed. The fryer will not function

 

if the drain valve is not fully

trouble light ON and

Open drain valve or problem with

closed. If the drain valve is fully

heating mode light

latching circuits

closed, the problem is within the

ON.

 

latching circuitry and is beyond the

 

 

scope of operator troubleshooting.

 

 

Call FASC.

6-6

Page 34
Image 34
Frymaster 8195915 Digital controller, display is in wrong, temperature scale, Fahrenheit or, Solid state controller