Problem | Probable Causes | Corrective Action | |
Digital controller |
| Digital controllers are manually set | |
| to display in one temperature scale | ||
display is in wrong |
| ||
| or the other. Refer to the separate | ||
temperature scale | Incorrect display option selected. | ||
Frymaster Fryer Controllers | |||
(Fahrenheit or |
| ||
| User's Manual for instructions on | ||
Celsius). |
| ||
| changing the display. | ||
|
| ||
|
| Verify that the drain valve is fully | |
Digital controller |
| closed. If the drain valve is fully | |
Open drain valve or problem with | closed, the problem is within the | ||
display shows | |||
latching circuits | latching circuitry and is beyond the | ||
. | |||
| scope of operator trouble shooting. | ||
|
| ||
|
| Call FASC. | |
|
| This in an indication of a | |
Digital controller | Frypot temperature is more than | malfunction in the temperature | |
control circuitry, including a | |||
410°F (210°C) or, in CE countries, | |||
display shows . | failure of the high limit thermostat. | ||
395°F (202°C). | |||
| Shut the fryer down immediately | ||
|
| ||
|
| and call FASC. | |
Digital controller |
| This indicates a problem within the | |
Problem with the temperature | temperature measuring circuitry | ||
display shows | measuring circuitry including the | that is beyond the scope of | |
. | probe. | operator troubleshooting. Shut the | |
|
| fryer down and call FASC. | |
|
| This in an indication of a | |
|
| malfunction in the temperature | |
|
| measuring or control circuitry, | |
Solid state controller | Oil temperature above acceptable | including a failure of the high limit | |
range or a problem with the | thermostat. Determining the | ||
trouble light ON. | |||
temperature measuring circuitry. | specific problem is beyond the | ||
| |||
|
| scope of operator troubleshooting. | |
|
| Shut the fryer down immediately | |
|
| and call FASC. | |
|
| Verify that the drain valve is fully | |
Solid state controller |
| closed. The fryer will not function | |
| if the drain valve is not fully | ||
trouble light ON and | Open drain valve or problem with | closed. If the drain valve is fully | |
heating mode light | latching circuits | closed, the problem is within the | |
ON. |
| latching circuitry and is beyond the | |
|
| scope of operator troubleshooting. | |
|
| Call FASC. |